WindO/I-NV4 User’s Manual
10-61
3 Picture Display
10
Da
ta
D
isp
la
ys
Value:
Switches the picture to display according to the value of the device address.
Example: When
Value
is selected and the trigger device addresses D0 are allocated to the
following pictures.
Switches the picture to display according to the value of the device address.
Trigger Device Address: Specifies the word device to use as the condition for switching pictures.
Click
to display the Tag Editor. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-70.
This option can only be configured when
Bit Number
or
Value
is
selected.
0
1
2
Trigger device address D0 value
Picture
Pic2
Pic1
Pic0
Pic 1
Pic 0
Pic 2
0
Picture to display
Trigger device address
D0 value
1
2
3
Display picture for 0
Action
Display picture for 1
Display picture for 2
No picture
If the value of device
address has no picture
associated with it, display
nothing.
When the size of pictures to switch differs and the
Dynamic Size
check box is cleared, all the pictures are
displayed with the same size as Pic0.
Fixed Period:
Switches the pictures to display at a regular interval in picture number order on the picture list.
Example: When
Fixed Period
is selected and the following pictures are allocated to the picture list.
Switches the pictures to display at a regular interval in picture number order on the
picture list.
Interval:
Specifies the interval to switch pictures as 2 to 600 (100 ms units).
This option can only be configured when
Fixed Period
is selected.
Repeat:
Select this check box to repeat displaying pictures from the start of the picture
list when the picture at the end of the list is displayed.
This option can only be configured when
Fixed Period
is selected.
Picture
Picture list number
Pic2
Pic1
Pic0
Picture to display
Action
5 x 100 ms
Interval
Regular interval
5 x 100 ms
Regular interval
5 x 100 ms
Regular interval
Display picture
for bit 0
Display picture
for bit 1
Display picture
for bit 2
Pic 0
Pic 1
Pic 2
If the
Repeat
check box is cleared,
stop switching the picture list.
When
Fixed Period
is selected, the picture may not be displayed when the interval is shorter than the scan
time for the screen on the MICRO/I. The maximum value for the MICRO/I scan time can be checked by the
value of HMI Special Data Register LSD4. Refer to Chapter 33 “HMI Special Data Register (LSD)” on page
33-8.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...