WindO/I-NV4 User’s Manual
11-37
2 Line Chart
11
Ch
arts
Data No.:
Out of the data contained in the selected Data Log channel number, specifies the data number to
display on the chart (1 to 128).
Double clicking the cell allows you to edit the data number.
Line Type:
Selects the type of line from the following.
Solid, Dot, Dash, Long Dash, Long Dash Dot, Long Dash Dot Dot
Double clicking the cell allows you to change the chart line type.
Line Size:
Selects the line size from the following.
1 dot, 2 dots, 3 dots, 5 dots
Double clicking the cell allows you to change the chart line size.
Line Color:
Selects the line color for the chart (color: 256 colors, monochrome: 16 shades).
Double clicking the cell displays the Color Palette where you can change the chart line color.
You can register the settings from arbitrary numbers, they are aligned filled from the beginning after clicking
OK
on the dialog box. Therefore, when the
Properties
dialog box is closed and reopened, the list is
displayed filled from the beginning.
Trigger Type: Always visible: Always display the graph.
While ON:
The graph is displayed when the value of device address is 1.
Device Address:
Specifies the bit device or the bit number of the word device to serve as condition.
Can only be set if
While ON
or
While OFF
is selected as
Trigger Type
.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 “5.1 Device Address Settings” on page 2-70.
Add:
Adds a channel to the list. Up to 20 channels total for all Y-axis.
Up:
Shifts the selected settings upward in the list.
Down:
Shifts the selected settings downward in the list.
Remove:
Deletes the selected contents from the list.
Data Log Settings:
Displays the
Data Log Settings
dialog box where you can configure the channel
while checking the data to display.
Always show chart
Chart state
0
20
40
60
80
100
-20
1
0
Hide chart
Show chart
Hide chart
Show chart
Show chart
Hide chart
Chart state
Value of
device address
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...