WindO/I-NV4 User’s Manual
13-5
1 Overview
13
Ala
rm
L
og
F
un
ctio
n
1.4 Data Configuration
The sampled data is composed of the channel number, level, message, alarm state, time, and label.
The relationship between the Alarm Log function settings and the sampled data is as follows.
1. Data storage amount: The amount of data that can be saved in the data storage area. For details, refer to “Data
2. Channel No.:
Composed of (Block No.)-(Channel No.). The device addresses to monitor and the
conditions for alarm occurrence and recovery are configured in the channels. When the
sampled data is output as a CSV file, the displayed label is “Ch.No.”.
3. Level:
It is the level of alarm.
Can only output when the
Output Alarm Level
check box in the
External Memory
Device
tab on the Alarm Log Settings dialog box is selected.
4. Message:
The message displayed when an alarm has occurred.
5. Alarm state and time: The alarm state (occurred, recovered, confirmed) and the time the alarm occurred, was
recovered from, and confirmed. When the sampled data is output as a CSV file, the
displayed label varies based on the output method.
6. Label:
When the sampled data is output as a CSV file, this is the text displayed in the label row.
This cannot be changed.
Ch.No.
Message
Occurrence Time Recovery
Time
Confirmation Time
1-1
Voltage drop
12/01/2011 12:00:05 12/01
12:01:10 12/01
12:01:30
1-2
Abnormal temperature 12/01/2011
12:01:09 12/01
12:02:21 12/01
12:02:55
1-1
Voltage drop
12/01/2011 12:02:00 12/01
12:03:11 12/01
12:05:12
1-3
Overcurrent 12/01/2011
12:30:21 12/01
12:55:15 12/01
13:00:00
1-1
Voltage drop
12/01/2011 12:45:36 12/01
12:53:12 12/01
12:57:41
Level
Level 8
Level 4
Level 8
Level 1
Level 8
1. Data storage amount
2. Channel No.
6. Label
3. Level
5. Alarm state and time
4. Message
Sampled data
Alarm Log settings
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...