4 Script Definition Method
20
Sc
rip
t
Arithmetic operation (Continued)
Data type conversion
Function
Format
Description
Arcsine
ASIN(
)
Arcsine of
(-1 - +1) in radian value (-π/2 - +π/2) is returned.
Specify arbitrary formula for argument
.
This function can only be configured when the
Float32(F)
is
specified as the
Data Type
.
Arccosine
ACOS(
)
Arccosine of
(-1 - +1) in radian value (0 - π) is returned.
Specify arbitrary formula for argument
.
This function can only be configured when the
Float32(F)
is
specified as the
Data Type
.
Arctangent
ATAN(
);
Arctangent of
(-1 - +1) in radian value (-π/2 - +π/2) is returned.
Specify arbitrary formula for argument
.
This function can only be configured when the
Float32(F)
is
specified as the
Data Type
.
Conversion from
Angle to Radian
RAD(
);
Value of
is converted from degree (°) to radian, and the value is
returned.
This function can only be configured when the
Float32(F)
is
specified as the
Data Type
.
Conversion from
Radian to Angle
DEG(
);
Value of
is converted from radian to degree (°), and the value is
returned.
This function can only be configured when the
Float32(F)
is
specified as the
Data Type
.
Function
Format
Description
Conversion from
BCD to Binary
BCD2BIN(
)
BCD value of
is returned in binary value.
This function can only be configured when
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
or
BIN32(L)
is specified as the
Data Type
.
Conversion from
Binary to BCD
BIN2BCD(
)
Binary value of
is returned in BCD value.
This function can only be configured when
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
or
BIN32(L)
is specified as the
Data Type
.
Conversion from
Floating point to
Binary
FLOAT2BIN(
)
Float32 value of
is returned in floating point value.
Values under the decimal point is truncated.
This function can only be configured when
UBIN32(D)
or
BIN32(L)
is specified as the
Data Type
.
Conversion from
Binary to Floating
point
BIN2FLOAT(
)
Binary value of
is returned in floating point value.
This function can only be configured when
UBIN32(D)
or
BIN32(L)
is specified as the
Data Type
.
Conversion from
Decimal to String
character
DEC2ASCII(
,
)
Decimal number value
is converted to a character string, and
store in order with
as a beginning device address.
This function can only be configured when
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
,
BIN32(L)
,
BCD4(B)
or
BCD8(EB)
is specified as the
Data Type
.
Conversion from
String character to
Decimal
ASCII2DEC(
)
Character string
is returned as decimal number value.
This function can only be configured when
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
,
BIN32(L)
,
BCD4(B)
or
BCD8(EB)
is specified as the
Data Type
.
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
b
b
a
a
a
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...