1 Communicating with the MICRO/I
24-8
WindO/I-NV4 User’s Manual
■
Search
Search for MICRO/I on the same network that can be connected to a computer via maintenance communication.
Click this button to display the
Search MICRO/I
dialog box. For details, refer to “Search MICRO/I dialog box” on
Target IP Address Settings dialog box
Specifies the IP address of the MICRO/I used for communication.
■
Target IP Address
Specify the IP address for the target MICRO/I to execute this function.
■
Target Port Number
Specify the port number for the target MICRO/I to execute this function.
■
After downloading, change the settings of Target
Change the IP settings of the target MICRO/I after project data is downloaded. Select from the following setting methods.
Use the IP Settings in "Communication Interface" tab on "Project Settings" dialog box:
Use the network settings configured in the
Communication Interface
tab on the
Project Settings
dialog box. For details, refer to Chapter 4 “When Ethernet is selected
under Interface Configuration” on page 4-41.
Use the following settings: Use the following IP settings. Select the check boxes to change items. Settings for which
the check box is clear are not changed.
IP Address:
Enter the IP address to register in the project data.
Subnet Mask:
Enter the subnet mask to register in the project data.
Default Gateway: Enter the default gateway to register in the project data.
Port Number:
Enter the port number to register in the project data.
Regarding TCP port number of MICRO/I, note the following points.
The numbers that cannot be used:
• 2539: Maintenance communication (Data Transfer)
• 2538: For pass-through
• 2101: For FC4A Series MicroSmart direct connection pass-through
Duplicate numbers cannot be configured in the following functions:
• Maintenance communication (
refer to Chapter 4 “Port Number” on page 4-41)
• Web server function (
refer to Chapter 4 “Port Number” on page 4-67)
• FTP server function (
refer to Chapter 4 “Port Number” on page 4-68)
•
TCP Server
is selected for the User Communication
(
refer to Chapter 4 “Port No.” on page 4-43)
•
Modbus
as
Manufacture
and
Modbus TCP Server
as
Communication Driver
are selected on
the
Communication Driver
tab
(
refer to the WindO/I-NV4 External Device Setup Manual)
•
YASKAWA Electric
as
Manufacture
and
MP2000(Ethernet)
as
Communication Driver
are
selected on the
Communication Driver
tab
(
refer to the WindO/I-NV4 External Device Setup Manual)
After downloading the OS, the settings of the target will be the IP settings in the
Communication
Interface
tab on the
Project Settings
dialog box.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...