4 E-mail Function
28-60
WindO/I-NV4 User’s Manual
●
Attach Files Dialog Box
Files attached to an e-mail is configured in the Attach Files dialog box.
■
Screenshot
Select this check box to attach a screenshot of the current screen to an e-mail.
The file format is JPEG and the file name becomes "Image.JPG".
■
Alarm Log Files
Select this check box to attach a specified alarm log data to an e-mail.
The file format is CSV and the file name becomes "ALMLOG.CSV".
Specifies the output format and the range of the alarm log data.
Output Format:
Specifies the items of the alarm log data attached to an e-mail.
Output Channel Number, Message, Occurrence Time, Recovery Time and Confirmaton Time:
The output data is the same format as the Alarm Log function batch outputs to the
external memory device. For details, refer to Chapter 13 “Batch” on page 13-38.
Output Channel Number, Message, State and Time:
The output data is the same format as the Alarm Log function outputs to the external
memory device in real time. For details, refer to Chapter 13 “Real Time” on page 13-39.
Range of Blocks:
Specifies the range of block numbers that will output in the collected alarm log data.
All:
Outputs the data for all blocks.
Specify block number: Outputs only the data for the specified blocks.
Individual block numbers can be specified by separating the num-
bers with “,”, continuous regions can be specified with “-”.
Example: When the number of blocks is 6, enter the following.
To specify blocks 1 to 3: 1-3
To specify blocks 1, 3, 6: 1, 3, 6
To specify blocks 1, 4 to 6:1, 4-6
Specify a period of time: Select this check box to specify the period of alarm log output data. Outputs the specified
period of the alarm log data after the Trigger Condition is satisfied.
Specify the maximum number of items:
Select this check box to specify the maximum amount of alarm log output data. Outputs the
specified number of the alarm log data after the Trigger Condition is satisfied.
When the
Specify a period of time
check box and the
Specify the maximum number of items
check
box are selected, the output range is until either is satisfied.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...