WindO/I-NV4 User’s Manual
4-45
3 Project Settings Dialog Box
4
Pro
je
ct S
ettin
gs
When USB1(USB-A) or USB2(USB-A) is selected under Interface Configuration
*4 HG2J-7U only
Function:
Selects the function used by the USB interface (Type A) from the following.
N/A
,
User Communication 1
,
User Communication 2
,
User Communication 3
,
Wireless LAN
,
Speaker
Access Point Setting: Configures the target access point to connect from MICRO/I via wireless LAN.
These options can only be configured when
Wireless LAN
is selected for
Function
.
Network Name (SSID): Enters the name (SSID) of the target access point. The network
name (SSID) is 1 to 32 characters.
Security Type:
WPA2-PSK
Password:
Enter a password. The password is 8 to 64 characters. Only
alphanumeric characters and symbols can be used.
Show Password: Select this check box to display the characters
entered in Password. When this check box is cleared,
the passwords are displayed with * (asterisk).
IP Settings:
Configure the IP address and subnet mask of the access point of the target. These options can
only be configured when
Wireless LAN
is selected for
Function
.
IP Address:
Specifies the IP address. (Default: 192.168.0.150)
The format is “xxx.xxx.xxx.xxx”. “xxx” stands for a numeric value
from 0 to 255.
When connecting multiple devices to the same network, make sure to
assign each device a unique IP address.
Subnet Mask:
Specifies the subnet mask. (Default: 255.255.255.0)
The format is “xxx.xxx.xxx.xxx”. “xxx” stands for a numeric value
from 0 to 255.
This value must be the same for all devices.
Port Number
:
Specifies the TCP port number (1 to 65535) to use for maintenance
communication. (Default: 2537)
Forbid Maintenance Communication:
Select this check box to prohibit maintenance communication via
wireless LAN communication.
Regarding TCP port number of MICRO/I, note the following points.
The numbers that cannot be used: • 2539: Maintenance communication (Data Transfer)
• 2538: For pass-through
• 2101: For FC4A Series MicroSmart direct connection pass-through
Duplicate numbers cannot be configured in the following functions:
• Maintenance communication
(
refer to “Port Number” on page 4-41)
• Web server function (
refer to “Port Number” on page 4-67)
• FTP server function (
refer to “Port Number” on page 4-68)
•
TCP Server
is selected for the User Communication
(
refer to “Port No.” on page 4-43)
•
Modbus
as
Manufacture
and
Modbus TCP Server
as
Communication Driver
are selected on the
Communication
Driver
tab
(
refer to the WindO/I-NV4 External Device Setup Manual)
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...