WindO/I-NV4 User’s Manual
4-83
4 Project Restrictions
4
Pro
je
ct S
ettin
gs
4.1 Download Restrictions
■
Project Data Size
The size of the project data that can be downloaded to the MICRO/I is as follows.
■
Number of Parts
The number of parts that can be downloaded to the MICRO/I are as follows.
4.2 Maximum Number of External Device Addresses
■
Data Log Settings
A maximum of 128 external device addresses can be used in the Data Log settings.
■
Global Script
A maximum of 256 external device addresses can be used as a trigger condition and in scripts executed as Global
Script.
■
Scripts
The number of external device addresses which can be used in the script are as follows:
4
Project Restrictions
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
MICRO/I
Project data size
HG5G/4G/3G/2G-V
Approx. 58 MB max (including additional fonts and Kanji Dictionary Data)
HG4G/3G, HG2G-5F, HG1G/1P
Approx. 12 MB max (including additional fonts)
HG2G-5T
Approx. 5 MB max (including additional fonts)
• To check the project data size, on the
Home
tab, in the
Project
group, click
Target Info.
The
Target
Information
dialog box is displayed. The project data size can be checked with
Memory Space (byte)
under
Target Runtime Information
.
• The project data size varies based on the fonts downloaded to the MICRO/I. For details, refer to Chapter
2 “Optional Fonts” on page 2-8.
Parts
Number of parts
Total number of Bit Buttons, Word Buttons, Goto Screen Buttons, Key Buttons
32,000 max.
Selector switches
200 max.
If the same device address is used in multiple device address settings, the number of used device addresses
is counted as 1. It is not counted as 1 device address per device address setting.
If the same device address is used in multiple device address settings, the number of used device addresses
is counted as 1. It is not counted as 1 device address per device address setting.
Item
Number of devices
Destination external device addresses
64 max.
Source external device addresses
64 max.
• If the same device address is used in multiple device address settings, the number of used device
addresses is counted as 1. It is not counted as 1 device address per device address setting.
• For the Global Script, the maximum number of source external device addresses which can be used as a
trigger condition and in scripts executed as Global Script is 256.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...