WindO/I-NV4 User’s Manual
8-97
5 Key Button
8
Bu
tto
ns
●
For Data Transfer Keys
These keys can be used to execute Data Transfer functions. For details about Data Transfer functions, refer to Chapter
29 “Data Transfer Function” on page 29-1.
●
For Alarm Displays
These keys can be used for the Alarm List Display and Alarm Log Display parts.
■
Alarm List Display
■
Alarm Log Display
*1 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F only
Key
Operation
Download Project
Downloads a project (ZNV Project File) saved on an external memory device to the MICRO/I.
Upload Project
Uploads the project used for operation on the MICRO/I and saves the ZNV Project File(.znv) to
an external memory device.
Copy Files
Copy files between and within external memory inserted in MICRO/I.
Download PLC Program Downloads a PLC program (ZLD Project File) saved on an external memory device to a PLC
connected to the MICRO/I.
Upload PLC Program
Uploads a PLC program from the PLC connected to the MICRO/I and saves the ZLD Project
File(.zld) to an external memory device
.
Key
Operation
Page Up
Scrolls up the number of lines (1 to 1023) specified in
Scroll Size
.
Page Down
Scrolls down the number of lines (1 to 1023) specified in
Scroll Size
.
Up
Moves the focus the number of lines (1 to 1023) specified in
Scroll Size
. The current point of
focus can be shown by pressing
Select
.
Down
Moves the focus the number of lines (1 to 1023) specified in
Scroll Size
. The current point of
focus can be shown by pressing
Select
.
Select
Toggles the focus between show and hide.
Reference
The reference screen appears.
Press and hold the
Page Up
,
Page Down
,
< Cur.
, and
Cur. >
keys for more than one second to move the
focus repeatedly.
Key
Operation
Up
Moves the focus the number of lines (1 to 1023) specified in
Scroll Size
. The current point of
focus can be shown by pressing
Select
.
Down
Moves the focus the number of lines (1 to 1023) specified in
Scroll Size
. The current point of
focus can be shown by pressing
Select
.
Select
Toggles the focus between show and hide.
Check
Shows the date and time the alarm that has focus was confirmed.
All Check
Shows the date and time that all alarms were confirmed.
Delete
Clears the alarm that has focus.
Delete All
Clears all alarms.
Reference
Shows the reference screen for the alarm that has focus.
Stop Buzzer and Screen
Flashing
Stops the sound of the buzzer and screen flashing when an alarm occurs.
Press and hold the
Up
and
Down
keys for more than one second to move the focus repeatedly.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...