SCR - Viper Safety Relays

 

SCR-31-i / SCR-21-i / SCR-31P-i 
 
The new generation of safety relays from IDEM 

 

Single or Dual channel operation  

 

The Viper Safety Relays range from IDEM are designed to meet the latest safety standards and 
offer enhanced LED diagnostics and simplified wiring. Applications include safety interlock 
switches, emergency e-stop devices door guard monitoring. The SCR-31P-i is design to be 
compatible with OSSD devices.(e.g. Light Curtains)  
 
The Viper Safety Relays range includes output expansion units that can be directly wired to SCR-
21-i / SCR-31-i / SCR-31P-i safety relays to increase the number of safety output contacts. The 
expansion modules are available with either immediate or time-delayed output contacts.  
 
The SCR-21-i / SCR-31-i / SCR-31P-i internal logic uses force guided relays to achieve cross 
monitoring, this ensures that a single fault does not lead to the loss of the safety function and that 
all faults are detected at or before the next safety demand. 

Monitored Manual or Auto Start/Reset  

Up to 3 Safety output contacts 
1 Auxiliary output contact 

(Depending on model No.) 

Contactor feedback check 

Easy diagnosis of status via 6 LEDs 

             

 

 
 

Up to PLe, SILCL 3, Category 4 

 

22.5mm DIN rail mounting 

24Vac/dc operation 

    

Emergency stop and guard interlock 
monitoring 

Output expansion units available to 
increase number of outputs. 

 

 

Functional Description 

When the control line inputs are closed and the start/reset condition 
has been met the safety output contacts close.                                                       
The safety relay outputs open when the inputs are de-activated or if 
there is a power failure. When dual channel inputs are used it is not 
necessary to synchronise switching of the input channels. 

 

 
When operating in the monitored manual reset configuration the 
reset button must perform a make-then-break action before the 
safety relay will activate.  
External device feedback contacts can be monitored via the reset 
loop. 
 

Block Diagram and Connections 

 

 

 

 

 

 

Terminal 

Description 

A1 

Power Supply 

A2 

Power Supply 

S11 

24Vd.c. Control voltage 

S12 

Control Line 

S13 

Control Line (SCR-21-i / SCR-31-i only) 

S14 

Control Line (SCR-31P-i only) 

S10 

Control Line 

S21 

Auto Start 

S22 

Monitored Manual Start 

13-14 

Safety Output Contact 1 

23-24 

Safety Output Contact 2 

33-34 

Safety Output Contact 3      (SCR-31-i / SCR-31P-i) 

41-42 
31-32 
 

Auxiliary Output Contact 1   (SCR-31-i / SCR-31P-i) 
Auxiliary Output Contact 1   (SCR-21-i) 
 

 

 

 

SCR-21-i / SCR-31-i

 

SCR-31P-i 