background image

                                             Non Contact Stand Alone Coded Safety Switches

 

 

IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR   UK.    Tel: +44 (0)1942 257070     Fax.: +44 (0)1942  257076 

IDEM (USA)  4416 Technology Drive, Fremont, CA 94538   Tel:510-445-0751  Fax:1866-431-7064  email:  

sales@idemsafety.com

  Web: 

www.idemsafety.com

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Standards: 

ISO14119  IEC60947-5-3  IEC60947-5-1  UL508  
ISO13849-1  EN62061   EN60204-1 

Safety Classification and Reliability Data: 

 

Power Supply 

24Vdc +/-10% (Consumption 150mA max.) 

Safety Output Maximum Rating 

240Vac/24Vdc  3A*  ac/dc 

 (*Max. current for QC is 2A)

 

Auxiliary Output Maximum Rating 

24Vdc 0.5A 

Dielectric Withstand 

4k Vac 

Insulator Resistant 

100 Mohms 

Recommended Setting Gap 

5mm 

Switching Distance 

Sao   10mm   Close 

(Target to Time) 

Sar   15mm    Open 

Tolerance to Misalignment 

5mm in any direction from 5mm setting gap 

Approach Speed 

600mm/m  to  1000mm/s 

Body Material 

PSA   High Specification Polyester 
MSA   Stainless Steel 316 

Temperature 

-25C/45C 

Shock Resistance 

IEC 68-2-27   11ms       30g 

Vibration Resistance 

IEC 68-2-6     10-55Hz  1mm 

Enclosure Protection 

PSA: IP67     MSA: IP69K/IP67 

Cable Type 

PVC   10 core   7mm OD 

Mounting Bolts 

2 x M4 

Quick Connect (QC) 

Flying Lead   250mm 

M12   8 way  Male Plug 

(Pin view from switch) 

 

Flying 

Lead 

Colours 

 

Circuit 

 

 

Red 

24Vdc 

24Vdc +/- 10% 

Blue 

Supply     0Vdc 

White 

Safety Output 1 (Force guided relay) 

AC15     240Vac   3A* 
DC13     24Vdc    3A* 

Black 

Safety Output 1 (Force guided relay) 

Yellow 

Safety Output 2 

AC15     240Vac   3A* 
DC13     24Vdc    3A* 

Green 

Safety Output 2 

Brown 

Reset/Check Circuit – Output 

 

Not Used 

Orange 

Reset/Check Circuit – Manual start 

 

Pink 

Reset/Check Circuit – Auto start 

 

Not Used 

Grey 

Auxiliary Feed 

Elec24Vdc  0.5A 

Safety Integrity Level 

SIL3 

 

PFH (1/h) 

3.95E-10 

Corresponds to 4.0% of SIL3 

PFD 

3.46E-05 

Corresponds to 3.5% of SIL3 

Proof Test Interval T

1

 

20a 

 

Performance Level 

 

Category 

Cat4 

 

MTTF

d

 

446a 

 

Diagnostic Coverage DC 

99%  (high) 

 

 

 

Doc: 102545 
June 2016 

CONNECTION EXAMPLE: Switches in series    PLe Cat.4 

 

Two switches connected in series to give dual circuit safety outputs to machine contactors. 

 

Safety Circuit 1 (Black/White) utilises internally checked force guided relay contacts and is 
connected in series with the corresponding Safety Circuit 2 (Yellow/Green) of the next 
switch. 
Allows minimal wiring and higher current switching to K1 and K2 contactors. 

 

A manual start and contactor feedback check is achieved by connecting K1(Aux) and 
K2(Aux) feedback contacts and momentary start button through the orange and brown 
feedback check. 
 

 
              SAFETY PRECAUTIONS: 

 

1. Installation and commissioning of the device must be performed 

only 

by authorised personnel. 

2. Observe the country specific regulations when installing the device. 
3. The wiring of the device must comply with the instructions in this user 
information - otherwise there is a risk that the safety function will be lost. 
4. External fusing of the safety contacts (a slow blow or 6A quick action 
must be provided). 
5. All relevant safety regulations and standards are to be observed. 
6. The overall concept of the control system in which the device is 
incorporated must be validated by the user. 
7. Failure to observe the safety regulations can result in death, serious 
injury and serious damage. 
8. Always use Safety Output 1. 

To request this data sheet in other languages please contact 

info@idemsafety.com

Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern 

info@idemsafety.com

Pour obtenir cette fiche en Français, veuillez contacter 

info@idemsafety.com

Para solicitar esta hoja de datos en Español, por favor contacto con 

info@idemsafety.com

 

EC/EU Declaration of Conformity 

MANUFACTURER: 

 

IDEM SAFETY SWITCHES LIMITED 

     

Hindley Industrial Estate, Hindley Green, Wigan, Lancashire WN2 4HR, United Kingdom

 

        

THE  LISTED  DEVICES  CONFORM  TO  THE  ESSENTIAL  HEALTH  AND  SAFETY  REQUIREMENTS  OF  THE  FOLLOWING  EUROPEAN  DIRECTIVES 
AND STANDARDS: 

Machinery Directive   

(2006/42/EC) 

EMC Directive 

 

(2014/30/EU) 

DEVICES:  NON CONTACT SAFETY SWITCHES:  
 

 

PSA    MSA   Standalone Coded Safety Switches  

 

 

STANDARDS (plus amendments):  

EN 60947-5-3 

 

2013 

EN ISO 13849-1: 

 

2008 + AC: 2010 + AC: 2013 

 
 

 

M.Mohtasham   Managing Director 
1

st

 May 2013    

 

Characteristic Data according to IEC62061 (used as a sub system) 

Characteristic Data according to EN ISO13849-1 

The calculation of the above values is based on the following assumptions: 
Number of operating days per year: 

d

op

 = 365d 

Number of operating hours per day: 

h

op

 = 24h 

Number of operating cycles per day: 

n

cyc

 = 1/d 

B10

 

 

= 150,000   AC1 Load   3A 

 

 

 

= 2,000,000   AC1 Load   0.5A 

When the product is used deviant from these assumptions (different load, 
operating frequency, etc.) the values have to be adjusted accordingly. 

*Max. current for Quick Connect is 2A. 
 

Information with regard to UL 508:   

Type 1 Enclosures.   
Maximum Temperature 45C 
Maximum Output 24Vdc  3A 
Use Class 2 Supply or equivalent 

Reviews: