General precautions
Do not expose the terminal to extreme temperatures.
When the environment is very dry, avoid synthetic carpeting near the
Morpho
Wave
Compact terminal, to reduce the risk of unwanted electrostatic
discharge.
Areas containing combustibles
Do not install the terminal in the vicinity of gas stations or any other installation
containing flammable or combustible gases or materials. The terminal is not
designed to be intrinsically safe.
The terminal should be installed in controlled lighting conditions
Avoid exposure of the biometric sensor to Direct sunlight
The terminal should be installed in controlled area in order to avoid water on the
sensor, ideally under a canopy.
Deployment Environments
The manufacturer cannot be held responsible in case of non-compliance with the
following recommendations or incorrect use of the terminal.
Repair and Accessories
Do not attempt to repair the Morpho
Wave
Compact terminal yourself. The
manufacturer cannot be held responsible for any damage/accident that may
result from attempts to repair components. Any work carried out by non-
authorized personnel will void your warranty.
Only use the terminal with its original accessories. Attempts to use unapproved
accessories with your terminal will void your warranty.
Date / Time synchronization
The Morpho
Wave
Compact terminal clock has a +/- 10 ppm typical time
deviation at +25ºC (r/- 1sec per day). At lower and higher temperature,
deviation may be greater (maximum : 8sec per 48 hours).
When the terminal is used for applications requiring high time precision, it is
strongly recommended to synchronize the terminal with an external clock.
Firmware release
To get the best of our technology, we recommend you to download and install
the last firmware release. Please check our website.
Recommendations
-10°to + 55 °C (14°to 131°F) when eco mode ON
-10°to + 45 °C (14°to 113°F) when eco mode OFF
Operating humidity
Storage temperature
Storage humidity
10 % < RH < 80 % (non condensing)
- 25°to + 70 °C (-13° to 158°F)
5% < RH < 95 %
IP code
IP65 rated
For UL 294 compliance, the products are rated for indoor use
Please apply eco mode feature accordingly to operating temperature
range in order to avoid over heating of the product
!
25 WIEG_OUT_LED1 Blue
28 WIEG_OUT_LED2 Blue / Red
23 WIEG_IN_D1
White / Red
24 WIEG_OUT_D0
Green
26 WIEG_OUT_D1
White
21 WIEG_IN_D0
Green / Red
27 WIEGAND_GND
Black / Red
7 RS422_RX_A
Blue / Black
8 RS422_TX_Z/RS485_B
Green / White
9 RS422_RX_B
Blue / White
10 RS422_TX_Y/RS485_A
Green / Black
11 RS422/485_GND
Black / Red
19 GPI2
Orange / Black
20 GPO2
Yellow / Black
17 GPI1
Orange / Red
18 GPO1
Yellow / Red
15 GPI0
Orange
16 GPO0
Yellow
22 GPIO_GND
Black / Red
13 RLY_NC
Orange / White
14 RLY_NO
Yellow / White
12 RLY_COM
Grey / White
5
SWITCH_PIN1
Light Blue
6
SWITCH_PIN2
Pink
1-3 Power +12V
Red
2-4 Power GND
Black
36 BI_DA+
Orange / White
1
34 BI_DA-
Orange
2
40 BI_DB+
Green / White
3
38 BI_DB-
Green
6
35 BI_DC+
Blue
4
33 BI_DC-
Blue / White
5
39 BI_DD+
Brown / White
7
37 BI_DD-
Brown
8
31 BI_GND Drain wire (no color) Shell
!
WARNING: Under powering
may cause memory and data
corruption; over powering may
cause hardware damage. Both
of these situations will void the
warranty
!
WARNING: Power Supply from electrical source shall be switched off before starting
the installation.
Before proceeding, make sure that the person in charge of installation and
connections, is properly connected to earth, in order to prevent Electrostatic
Discharges (ESD).
RJ45
External Power supply:
12/24 VDC (regulated and filtered) 2.5 A min @12VDC or
1.25 A min @24VDC, IEC/EN EN60950-1 standard compliant. If sharing power
between devices, each unit must receive 2.5 A (e.g. two units would require a 12 VDC,
5 A supply).
For UL compliance the units shall be powered via a class 2 output from a UL 294 power
supply.
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is
recommended.
Power Over Ethernet Plus (POE+):
power can be provided through RJ-45 connector
using a PSE (Power Sourcing Equipment)
IEEE802.3at type 2
compliant.
For UL compliance the units shall be powered via a UL 294B PSE power supply.
The terminal is a Class 4 (25.5 W) PD (Powered Device).
IDEMIA recommends using a 24V power
supply and AWG16 gauge cable. The
voltage measured on the product block
connector of the terminal must be equal to
12V-24V (-15% / +10%).
The voltage drop due to the cable shall be
taken into account. The table below shows
the maximum distance between power
supply and 1 unique device, depending on
cable gauge and power supply rating.
Operating temperature
Wiring Overview
WARNING: Cleaning & Disinfection precautions
To clean the terminal, a dry cloth is recommended, especially the
biometric sensor.
To remove the dust out of the sensor glass, use dry air spray.
To disinfect the terminal, moisten a non-abrasive wipe with the
disinfectant Windex® Multi-Surface (or similar product containing L-
Lactic acid) or hydrogen peroxide (<3%) and wipe the device’s surface
and leave the surface wet with disinfectant for at least 5 minutes. Any
other practices (bleach, chlorine, soda, alcohol, quaternary ammonium
etc) permanently damage and/or negatively impact the performances of
the device.
!
Maximum distance (meters)
vs power source rating
Gauge
AWG
Section
(mm²) 12V
+/-10%
12V
+/-5%
24V
+/-10%
20
22
18
16
0.82
0.52
0.32
9 m
6 m
3 m
2 m
20 m
12 m
8 m
5 m
300 m
200 m
120 m
75 m
1.31
For UL installations only Wiegand is to be used.
UL has not evaluated GPIO and RS422/485 communication.
UL has not verified Wi-Fi Capabilities.
Ethernet connection is for supplemental use not UL evaluated.
Relay output
30VDC, 1 A (Resistive).
Tamper
30VDC, 100 mA (Resistive).