Regulatory, safety and environmental notices
Products bearing the CE marking comply with one or more of the following EU Directives as may be applicable:
•
Low Voltage Directive 2006/95/EC
•
EMC Directive 2004/108/EC
•
R&TTE Directive 1999/5/EC
•
Ecodesign Directive 2009/125/EC
•
RoHS Directive 2011/65/EU.
Compliance with these directives is assessed using applicable European Harmonised Standards.<<<
The installation of this product should be made by a qualified service Person and should comply with all local regulations.
It is strongly recommended to use a class II power supply at 12V-24V and 2.5 A. min (at 12V) in conformity with Safety Electrical Low Voltage
(SELV). The power supply cable length should not exceed 10 meters.
This system must be installed in accordance with the National Electrical Code (NFPA 70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying with IEC60950-1, in accordance with the NEC Class 2 requirements; or
supplied by a listed IEC60950-1 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 2.5 A minimum or 24VDC,
1.25 A minimum.
In case of building-to-building connection it is recommended to connect 0V to ground. Ground cable must be connected with the terminal block
Power Ground.
Note that all connections of the MorphoWave Compact terminal described hereafter are of SELV (Safety Electrical Low Voltage) type.