43
MorphoWave Compact - 2018_2000035853
4.2 > Power Supply
PoE+ and external power supply are not used at the same time: if both power supplies are used, priority
is given to external power supply. If external power supply is shut down, switch to PoE+ without reboot is
not guarantee.
External Power supply
Figure 10: Power supply wiring
1-3
Red
Power Supply 12-24V DC
In
Positive 12-24 Volts, power supply
2-4
Black Power ground
In
Ground power supply
The External power supply
Must comply with IEC 60950-1 standard marked Class 2, Limited Power source (LPS)
12V to 24V Dc (regulated and filtered) 2.5 Amp min at 12V.
If sharing power between devices, each unit must receive 2.5A (e.g. two units would require a 12vDC,
5A supply).
IDEMIA recommends using a 24V power supply and AWG16 gauge cable. The voltage measured on the
product block connector of the terminal must be equal to 12V-24V (-15% / +10%).
The voltage drop due to the cable shall be taken into account. The table below shows as an example the
maximum distance between power supply and one (1) unique device, depending on cable gauge and
power supply rating.
Gauge
AWG
Section
(mm
2
)
Maximum distance (meters)
vs power source rating
12V
+/-10%
12V
+/-5%
24V
+/-10%
16
1.31
9 m
20 m
300 m
18
0.82
6 m
12 m
200 m
20
0.52
3 m
8 m
120 m
22
0.32
2 m
5 m
75 m
If several terminals are powered by the same cable, make sure to select a wire gauge that
complies with maximum voltage drop, cable length, and power source minimum voltage
rating.
Summary of Contents for MorphoWave Compact
Page 1: ...Copyright 2018 Idemia May 2018 2018_2000035853 MorphoWave Compact Installation guide ...
Page 2: ...Copyright 2018 Idemia May 2018 2018_2000035853 ...
Page 9: ...9 MorphoWave Compact 2018_2000035853 1 Introduction ...
Page 21: ...21 MorphoWave Compact 2018_2000035853 2 General description ...
Page 29: ...29 MorphoWave Compact 2018_2000035853 3 Installation procedure ...
Page 37: ...37 MorphoWave Compact 2018_2000035853 3 3 4 Attach the device on the base plate ...
Page 41: ...41 MorphoWave Compact 2018_2000035853 4 Electrical interface ...
Page 58: ...58 MorphoWave Compact 2018_2000035853 5 User interface ...
Page 64: ...64 MorphoWave Compact 2018_2000035853 6 Accessories Software Licenses and PC Applications ...
Page 67: ...67 MorphoWave Compact 2018_2000035853 7 Recommendations ...
Page 70: ...70 MorphoWave Compact 2018_2000035853 8 Annex 1 finger placement recommendations ...
Page 74: ...74 MorphoWave Compact 2018_2000035853 ...
Page 75: ...75 MorphoWave Compact 2018_2000035853 9 Annex 2 Bibliography ...
Page 78: ...78 MorphoWave Compact 2018_2000035853 10 Annex 3 Support ...
Page 80: ...Copyright 2017 Photo GettyImages 656164914 Copyright 2017 Photo GettyImages 656164914 ...