MSO Fingerprint scanners Installation Guide
Error! Use the Home tab to apply Titre 1 to the text that you want to appear here.
2018_2000039830
October 2021
This document and the information therein are the property of IDEMIA. They must not be copied
or communicated to a third party without the prior authorization of IDEMIA
21
6.1.2 Temperature range and humidity
Device
Temperature range
Humidity
Operating
Storage
Operating
Storage
MSO1350
0°C to 50°C
- 20°C to 70°C 10% < RH < 85%
RH < 95%
Table 9: MSO 1350 devices, temperature and humidity range
6.1.3 IP rating
Device
IP rating
MSO1350
(which integrates a CBM OEM)
IP65 rated sensing window
Table 10: MSO 1350 devices, IP rating
The table above defines also the maximum value of the IP (ingress protection) rating which
can be reached by a product which integrate (according to the appropriate
recommendations) an OEM model.