IDEMIA DOCUMENT
– REPRODUCTION AND DISCLOSURE PROHIBITED
Wiring Overview
293732943-F
9
St
ep
tw
o
:
w
iring
RJ-45
USB
µSD
RS422 / RS485
17
R (A)
Blue / Black
15
RS422_RX- (B)
Blue / White
16
R / 485_TX/RX+ (Y)
Green / Black
18
RS422_TX- / 485_TX/RX- (Z)
Green / White
19
RS422/485_GND
Black / Red
Wiegand IN & Wiegand OUT
22
WIEGAND_IN0
Green / Red
23
WIEGAND_IN1
White / Red
20
WIEGAND_GND
Black / Red
24
WIEGAND_OUT0
Green
21
WIEGAND_OUT1
White
25
WIEGAND_LEDOUT1 Blue
26
WIEGAND_LEDOUT2 Blue / Red
GP IN & OUT
8
GPIO_GND
Black / Red
9
GPI0
Orange
11
GPI1
Orange / Red
13
GPI2
Orange / Black
10
GPO0
Yellow
12
GPO1
Yellow / Red
14
GPO2
Yellow / Black
Power supply, Tamper switch & Relay
1
Power +12V
Red
2
Power GND
Black
3
SWITCH_PIN1
Light Blue
4
SWITCH_PIN2
Pink
5
RLY_NO
Yellow / White
6
RLY_COM
Grey / White
7
RLY_NC
Orange / White
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
Power supply from electrical source shall be switched off before starting the installation.
Before proceeding, make sure that the person in charge of installation and connections, is properly connected to
earth, in order to prevent Electrostatic Discharges (ESD).
Backup of the Date/Time of the terminal:
the volatile settings (such as date/time) of the terminal are protected against
power failure, by a dedicated component during a least 24 hours (at 25
o
C) without external power supply.