General

In principle, the ILR system is maintenance-free. When correctly installed it operates for many years without
any problems.

4.2

 

Precautionary Maintenance

Regular checking to the system is recommended. Make sure that the housing of the tag has no damage. If
there are any damages as holes or cracks, the tags should be replaced and returned to 

IDENTEC

SOLUTIONS 

immediately.

Regular checking of all ports and cables belonging to the system is recommended. Unstable connections could
lead to damage and malfunctions of the system and therefore should be repaired as soon as possible.

A Brief Checklist

 

Are all housings intact?

 

Are all cables intact?

 

Are all connectors intact?

 

Are all connectors securely fastened?

 

Are all screws still tight?

 

Is there suddenly a malfunction at a specific unit?

4.3

 

Returns

Parts or main components returned for repair or exchange must be handled with great care. PC cards must be
returned in the appropriate ESD-protecting packaging material.
All returns should include a completed returns form (see appendix) and be sent to the local distributor or to:

IDENTEC SOLUTIONS AG
Service Department
Millenium Park 2
6890 Lustenau
AUSTRIA / AUTRICHE

Summary of Contents for i-Q350L M

Page 1: ...i Q350L M Microtag Manual...

Page 2: ...ithout limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility...

Page 3: ...ean Notification according R TTE Directive This equipment complies to Art 6 4 of R TTE Directive 1999 5 EC It is tested for compliance with the following standards ETSI EN 300 220 ETSI EN 301 489 EN 6...

Page 4: ...SCOPE OF THIS DOCUMENT 5 1 4 RESPONSIBILITY 5 1 5 ASSOCIATED DOCUMENTS 5 1 6 SCOPE OF DELIVERY VISUAL INSPECTION 5 2 SAFETY PRECAUTIONS 6 3 INITIAL OPERATION 8 3 1 CONFIGURATION OF THE TAG 8 3 2 TAG H...

Page 5: ...ck of the tags and a system test can now be done 1 3 Scope of this Document This document is the user s manual of the model i Q350L M This document is intended only for mechanical installation rsp eve...

Page 6: ...of 70 C 158 F care must be taken if the tags are heated To avoid burn wait a while until the tags have cooled down or use gloves At temperatures below 0 C 32 F tags can be iced In this case wait a wh...

Page 7: ...only original products spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation service and repair Otherwise IDENTEC SOLUTIONS does not accept any responsibility for mater...

Page 8: ...o be configured The ping rate from 0 5 to 300 seconds in steps of 0 5 seconds The number of bursts from 0 to 15 factory default setting 5 Broadcast Telegram Mode ILR B2 ASK compatible with i PORT MB i...

Page 9: ...ble connections could lead to damage and malfunctions of the system and therefore should be repaired as soon as possible A Brief Checklist Are all housings intact Are all cables intact Are all connect...

Page 10: ...e Transmits marker information in at regular intervals Repetition rate ping rate 0 5 300 seconds adjustable in steps of 0 5 seconds Data rate broadcast 115 2 kbits s The communication range depends on...

Page 11: ...350L M Page 11 of 11 Mechanical Data Dimensions 56 mm 30 mm 14 mm Casing Plastics Mass 40 g Protection class IP 65 Certifications EMC CE EN 300 220 1 3 ETSI EN 301 489 1 3 FCC Part 15 US Industry Cana...

Reviews: