R&D
Access Touch 2.0 – User Manual
Version 1.03
Public
5 (12)
Author: Hal
File: C00320E
Date:
18.8.2012
Approved:
Jpo
Printed:
20.08.2012
09:45
Idesco Oy | Teknologiantie 9, FIN-90590 OULU | Tel +358 20 743 4175 | info@idesco.fi | www.idesco.fi
CONNECTOR 1
CONNECTOR 2
CONNECTOR 3
CONNECTOR 4
CONNECTOR 5
ETHERNET CONNECTOR
USB 1
USB 2
USB 3
Picture 2: Access Touch 2.0 connections
5.2.1.
Connector 1
Connector 1 includes the power supply, RS485, and wiegand hubs
Picture 3: Connector 1
5.2.1.1.
Power supply
Input voltage: 15...30 VDC
Power requirements / average current consumptions:
850 mA @ 15 VDC
520 mA @ 24 VDC
Choose a power supply that meets the above power requirements.
5.2.1.2.
Wiegand hubs A and B
Two wiegand readers can be connected with the wiegand A and wiegand B hubs. Two open collector
outputs OUT A and OUT B may be used for controlling wiegand reader inputs (e.g. reader LED con-
trol)