Page 12
0901048 Rev. C
Description of Screen
Display
If TEMP is flashing on the blue runtime screen, the temperature of the water is not within the predefined range. Adjust the
water temperature before dispensing.
If TEMP OUT OF RANGE is displayed in green, the temperature of the water is not within the predefined range.
If the Chemical empty! Alert is displayed in red, the detergent container is empty and needs to be replaced and the unit re-
primed. Replace the detergent container then press START to begin automatic re-printing.
17:05:56AM
08/15/13
LAST DOSE VOLUME
000
LEVELS A&B
025/050
ALARMS TODAY
000
TEMP OUT OF RANGE
Chemical empty!
Replace Chemical Container,
then press START button.
DoseTech DMS Runtime Alerts
Symptom
Solutions/Cause
Temperature Alarm will not shut off
Adjust temperature range
Adjust water temperature
Dosing Alarm will not shut off
Detergent container empty
Recalibrate detergent pump
Detergent discharge tube worn or broken
Can’t access system menus
Reboot the system
User interface switch inoperable
Pump tube broken or worn
Replace with factory tube only
Summary of Contents for Knight DoseTech DMS
Page 1: ...Instruction Manual 0901048 Rev C...
Page 16: ...Page 16 0901048 Rev C DoseTech DMS Parts Diagram...
Page 17: ...0901048 Rev C Page 17 DoseTech DMS Wiring Diagram...
Page 18: ...Page 18 0901048 Rev C...
Page 19: ...0901048 Rev C Page 19 Notes...
Page 20: ...Page 20 0901048 Rev C Notes...
Page 21: ...0901048 Rev C Page 21 Notes...
Page 22: ...Page 22 0901048 Rev C DoseTech DMS Mounting Template...
Page 23: ...0901048 Rev C Page 23...
Page 25: ...0901048 Rev C Page 25...