Install drain plug (5), where required in required position in gearbox cover
(16).
-
If not already installed, mount feet (1) to rotorcase (40) in the required
positions using cap screws (2). Install the seal sleeve (if required) see
section 4.3.
Fig 14 Gearbox & Rotorcase Assembly.
4.2.2 Shaft Assembly – RTP20
-
Install front bearing (24) to the shaft (9 or 10).
-
Install O-rings (26 and 25), to shafts (9 or 10) in the appropriate grooves.
Lightly lubricate all O-rings with a compatible lubricant.
-
Install the gear (14) over the O-rings (26) and secure with retaining bolts
(23). It is recommended that the screws be aligned at the centre of the
slots provided to give an equal amount of adjustment in either direction.
Summary of Contents for Wright Flow Technologies RTP Series
Page 1: ...P Pa ag ge e 0 0 INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR THE RANGE OF PUMPS...
Page 47: ...P Pa ag ge e 4 46 6 5 0 Specifications 5 1 Clearance Chart B A C Radial D C Radial...
Page 54: ...P Pa ag ge e 5 53 3 5 6 Typical Basic Pump Build RTP20 Shown...
Page 56: ...P Pa ag ge e 5 55 5 5 8 RTPTM Service History Pump Serial No Date Comments...