Specifications

These product specifications may change without prior 
notice.

General

Exterior Dimensions  

(W x H x D)

300mm x 62mm x 232mm

Weight (Main Unit)

2.9kg(with 2TB 2HDDs)

Working Temperature / 

Operating Humidity

0°C – 40°C / 0% – 90%

Power Input

ADAPTOR (INPUT: 100V~240V AC, 50/60Hz, 
1.5A / OUTPUT: 12V DC, 5A)

Power Consumption

12V

, 1.3A, 15.6W

Certifications

FCC, CE

Video

Video In

Composite or HD-TVI : 4 inputs, 1 Vp-p, 
auto-terminating, 75 Ohms

Monitor Out 

HDMI: 1, VGA: 1

Video Resolution

HDMI: 1920x1080, 1440x900, 1280x1024
VGA: 1920x1080, 1440x900, 1280x1024

Recording Speed (IPS)

Real-time: 120ips @ Full HD

Playback Speed (IPS)

Full Duplex: 60ips @ Full HD

I/O

Alarm In

4 TTL, NC/NO programmable, 2.4V (NC) or 
0.3V (NO) threshold, 5VDC

Alarm Out

1 relay output, terminal blocks, NO 
programmable, 2A@125VAC, 1A@30VDC

Internal Buzzer

78dB at 10cm

Network Connection

10Mbps/100Mbps Ethernet

Audio In / Audio Out

4 lines, RCA / 1 line, RCA

Text In

POS Interface, ATM Interface

Connector

Video In

Composite or HD-TVI : 4 inputs, 1 Vp-p, 
auto-terminating, 75 Ohms

Monitor Out

HDMI: 1, VGA: 1

Audio In / Audio Out

4 RCA connectors / 1 RCA connector

Alarm

Terminal blocks

Ethernet Port

1 RJ-45

RS232 Serial Port

Terminal blocks

RS485 Serial Port

Terminal blocks

IR Remote Control Port

Remote Control

USB Ports

2 x USB 2.0

Storage

Primary Storage

SATA hard disk drive

Secondary Storage

USB hard disk drive or flash drive

Clip Copy Device

USB Storage Device (USB HDD, USB 
Memory, etc.)

V1.8

Summary of Contents for TR-2204

Page 1: ...TR 2204 Digital Video Recorder Quick Guide...

Page 2: ...g this equipment from the wall outlet and refer servicing to qualified service personnel under the following conditions A When the power supply cord or the plug has been damaged B If liquid is spilled...

Page 3: ...SMEETSALLREQUIREMENTSOFTHECANADIANINTERFERENCECAUSINGEQUIPMENT REGULATIONS WEEE WasteElectrical ElectronicEquipment Correct Disposal of This Product Applicable in the European Union and other European...

Page 4: ...e to ensure that all the following accessories are included Item Digital Video Recorder Power Cable Quick Guide Optical USB Mouse IR Remote Control Please download IDIS Center software and product man...

Page 5: ...orts 3 HDMI Out Port 4 VGA Out Port 5 Network Port 6 Alarm Connection 7 RS232 Port 8 RS485 Port 9 Power In Port Connections on the Rear Panel Microphone Speaker VGA Monitor HDMI Monitor Sensor Keyboar...

Page 6: ...press the Setup button on the remote control or click on Log in using the mouse 2 Select a user enter the password and then select OK If you do not know the password click the button for guidance Ther...

Page 7: ...Method Setup Record Video Quality Setup Higher recording quality uses up more disk space Finish the Quick Setup Wizard Network Setup Wizard After exiting from Quick Wizard you can click Go to Network...

Page 8: ...Panic Recording icon or press the Panic Recording button again If the Panic Recording Time option under Record Setup General has been configured Panic Recording will automatically terminate after the...

Page 9: ...er the following information in the address bar http IP Address Port Number DVR system s IP address and WebGuard port number configured under Network General Default Value 12088 Or http fen idisglobal...

Page 10: ...tup folder in the downloaded file and run setup exe On Microsoft Windows Vista or User Account Control window may pop up Click Allow and follow the instructions in the installation window to proceed w...

Page 11: ...er ID is admin without a password You can change User ID and Password in the User menu Device Registration To use the functions provided by IDIS Center you must first register a device and add the dev...

Page 12: ...ce group will be displayed on the right To modify a device group that has been registered select a device group and click E on the bottom of the Sites panel Modify Device Group window will appear You...

Page 13: ...ce s IP address For port number using the default value is recommended User ID Password Enter the User ID and Password used to login to the device Default value of User ID admin No default value of pa...

Page 14: ...ll Duplex 60ips Full HD I O Alarm In 4 TTL NC NO programmable 2 4V NC or 0 3V NO threshold 5VDC Alarm Out 1 relay output terminal blocks NO programmable 2A 125VAC 1A 30VDC Internal Buzzer 78dB at 10cm...

Page 15: ......

Page 16: ...IDIS Co Ltd For more information please visit at www idisglobal com...

Reviews: