FDX-32 User
’s Guide
24
6.2.2 SFP module
The fiber type and extension distance to be used vary depending on the SFP module.
[Table 6.2] Specifications of standard SFP modules
* The lasers in this product meet Class 1 Laser Safety per FDA/CDRH and EN (IEC) 60825 laser
safety standards which specify design safety.
* Some SFP modules for singlemode can extend the transmission distance up to 30 km with OS1.
Please contact us if needed.
● Plug the dust cap to the fiber optical cable if you do not use it.
● Do not use the SFP module for other devices. Do not connect the optic fiber cable that is connected to
other devices to the SFP module; otherwise, the SFP module may be broken.
● If you need to replace the SFP module, please contact us.
Multimode fiber
Singlemode fiber
Wave length
850 nm (Oxide VCSEL laser*) 1310 nm (Fabry-Perot laser*)
Maximum extension distance
OM3: 300 m/984.25 feet
OM4: 1 km/3280.84 feet
OS1: 4.7 km/15419.94 feet
Input level
-13 dBm or higher
-18 dBm or higher
Output level
-9 dBm to -2.5 dBm
-8.4 dBm to -3 dBm
Max. optical receiving level
0 dBm
+
0.5 dBm
Connector
LC (Duplex)