8.17 [ F38 ] Setting CEC physical address copy of EDID
CEC: Pass through between IN and HDC OUTPUT.
The CEC physical address of the sink device that is connected to HDC OUTPUT into the EDID of IN. can be
copied
If the CEC physical address of the connected sink device and the HDC’s address are not the same, the CEC
functions, such as input switching in the sink device at start-up, may not work correctly. The problem can be
solved by using the CEC physical address that is copied into the HDC.
on: Copy physical address
oFF: Not copy physical address [Default]
Notes:
● This is enabled if CEC-supported source and sink devices are connected and one of 03 to 22 is selected
for resolution setting of EDID.
● CEC system link functions supported by other companies are not guaranteed to work correctly by this
setting. Check the actual configuration.
・
Setting by menu
Normal condition (OFF)
↓ SET key
“
-
” “
+
” key set INPUT EDID physical address copying
→ select F38
↓ SET key
“
-
” “
+
” key set
Copy physical address [Default:
OFF]
OFF
:
EDID physical address copy OFF ON
:
EDID physical address copy ON
↓
During EDID physical address copying is processing, READY LED is OFF. After setting is
finished, the LED is ON
↓
After processing, 7-SEGMENT LED goes back to menu.