7
Error codes are replied in the following order:
Video output to HDMI output port, audio output to HDMI output port, audio output
to analog audio output port.
Error code
Video output status
Audio output status
0
Video or audio is output correctly. *
7
1
-
“@SAM Set output mute (P. 62)”
is set to “ON”
2
Only replied if digital input, which means DDC power is not input.
(Normally, if input device is not connected, this error code is
displayed)
3
Video signal is not input
Audio signal is not input
4
Only replied if digital input, which means video or audio output of the
source device is muted
5
Only replied if digital input, which means signal with HDCP is input
but display device is HDCP incompliant (This error code may be also
replied during HDCP authorization)
6
Only replied if digital input, which means source device does not
output the required information (packets) for output of video or audio
7
Signal that is not supported by
MSD-804FD (Sampling clock is
out of range) is input.
Since compressed audio is input,
audio cannot be output
(Compressed audio can be
output only to display devices
supporting compressed audio).
8
-
“@SDO Set audio output
connector (P. 66)” is set to “OFF”.
9
-
“@SDM Set output mode (P. 51)”
is set to “DVI MODE” or a display
device that does not support
audio is connected.
*8
A
Input channel is set to “OFF”
B
-
“@SAOSet digital audio output
connector” (P.67) is set to “OFF”.
C
Display device is not connected
D
Authorizing HDCP
E
HDCP authorization failed
*
F
Cat5e/Cat6 cable is not connected.
*8
*
7
Analog audio input status cannot be detected. Even if “0” is replied, audio may not
be output with analog input selected.
*