MSD-804FD Users Guide (Command Guide)
41
@SST Set
saturation
Command
format
@SST,
ch_1
,
saturation_1 (
,
ch_2
,
saturation_2
・・・
)
Return value
format
@SST,
ch_1
,
saturation_1 (
,
ch_2
,
saturation_2
・・・
)
Parameter
ch_1-9
: Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
saturation_1-9
: Input saturation
0 to 200 [Default]: 100
Example Send
Receive
@SST,5,105
@SST,5,105
Set input saturation of IN5 to 105%.
Terminated normally.
Related info.
8.4.4 Saturation
@GST Get
saturation
Command
format
@GST
Return value
format
@GST,
in_1
,
in_2
,
in_3
,
in_4
,
in_5
,
in_6
,
in_7
,
in_8
,
in_9
Parameter
in_1-9
: Input saturation of each input channel
0 to 200 [Default]: 100
Example Send
Receive
@GST
@GST,100,100,100,100,105,100,
100,100,100
Get input saturation.
IN5: 105% and other inputs: 100%.
Related info.
8.4.4 Saturation
@SSU
Set black level
Command
format
@SSU,
ch_1
,
setup_1 (
,
ch_2
,
setup_2
・・・
)
Return value
format
@SSU,
ch_1
,
setup_1 (
,
ch_2
,
setup_2
・・・
)
Parameter
ch_1-9
: Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
setup_1-9
: Input setup level
-20 = -20×0.5 (-10.0 %) to +20 = +20×0.5 (+10.0 %) [Default]: ±0 = ±0.0%
Example Send
Receive
@SSU,5,15
@SSU,5,15
Set input setup level of IN5 to +7.5%.
Terminated normally.
Related info. 8.4.5 Black level