background image

PDU-1209  Use

r’s  Guide 

 

 
 
 
 
 
 

Prohibition 

Do not place the product in any unstable place. 

Install the product to a horizontal and stable place. Otherwise, it may fall/turn over and lead to injury.

 

Do not place the product in any environment with vibration. 

Otherwise, it may move/fall and lead to injury.

 

Keep out any foreign objects. 

In order to avoid fire or electric shock, do not allow foreign objects, such as metal and paper, to enter the product 
from the vent holes.

 

For power cable/ plug: 

 

Do not scratch, heat, or modify, including extending them.

 

 

Do not pull, put heavy stuff on them, or pinch them. 

 

Do not bend, twist, or tie them together forcefully. 

If they are used in those states continuously, it may cause fire or electric shock. If power cables/plugs become 
damaged, contact IDK. 

 

 
 

 

Do not 

disassemble 

Do not repair, modify or disassemble. 

Since the product includes high-voltage part, those actions may cause fire or electric shock. For internal inspections 
or repairs, contact IDK.

 

 

 
 

Do not 

touch 

In the event of lighting or thunder, do not touch the main unit and cables such as 
power cable and LAN cable. 

Contact may cause electric shock

 

 
 
 
 

 
 
 

Instruction 

For installation: 

The product is intended to be installed by skilled technicians. For installation, please contact a system integrator or 
IDK. Otherwise, it may cause fire, electric shock, injury, or property damage.

 

Set the power plug in a convenient place to unplug easily. 

You can easily unplug in case of any extraordinary failure or abnormal situation, and it also helps for unplugging 
when you do not use it for a long period. 

 

Plug the power plug into appropriate outlet completely. 

If the plug is plugged incompletely, it may overheat which causes electrical shock or fire. Do not use damaged plug 
or loosened outlet.

 

Clean the power plug regularly. 

If the plug is covered in dust, it may cause fire due to reduced insulating power.

 

 
 
 
 
 

Unplug

 

Unplug immediately if the product smokes, makes unusual noise, or smells. 

If you continue to use the product under those situations, it may cause electric shock or fire. After confirming that the 
product stops smoking, contact IDK.

 

Unplug immediately if you drop the product or if the cabinet is damaged. 

If you continue to use the product under those situations, it may cause electrical shock or fire. For maintenance and 
repair, contact IDK.

 

Unplug immediately if water or other objects are directed inside. 

If you continue to use it under those situations, it may cause electrical shock or fire. For maintenance and repair, 
contact IDK.

 

For connection 

 

Instruction

 

Differences in ground potential among the product and external devices may cause electric shock or damage of the 
devices. When using cables to connect devices, including connection of long-distance transmission, unplug the 
power cables of all related devices. 
After connecting signal/control cables of each device, plug in the power cables of each device. 

 

 

 

 

 

 

Warning

 

 

 

 

Summary of Contents for PDU-1209

Page 1: ...U 1209 User s Guide Ver 1 0 0 Thank you for choosing this IDK product To ensure the best performance of this product please read this User s Guide fully and carefully before using it and keep this man...

Page 2: ...finition Multimedia Interface and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries All other company and product names mentioned in...

Page 3: ...gy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Page 4: ...y if the warning is ignored or the equipment is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the equipmen...

Page 5: ...e Set the power plug in a convenient place to unplug easily You can easily unplug in case of any extraordinary failure or abnormal situation and it also helps for unplugging when you do not use it for...

Page 6: ...he product in humid oil smoke or dusty place If the product is placed near humidifiers or dusty area it may cause fire or electric shock Do not block the vent holes If ventilation slots are blocked it...

Page 7: ...so may shorten the life of the internal parts and result in malfunctions Fuse For products having a fuse holder Products with a fuse holder the fuse can be replaced with a new one Follow the detailed...

Page 8: ...em configuration example 13 6 Precautions and preparations 14 6 1 Attaching Rubber feet 14 6 2 Installation 14 6 3 Cabling 15 6 3 1 Connecting to compatible models 16 6 3 2 Connecting alarm 17 7 Alarm...

Page 9: ...DIN plug DC cable with a lock 4 9 ft 1 5 m 9 2 pin terminal block 1 Rubber feet 4 Fig 1 1 Included items Note Follow the instructions below to prevent fire and electrical shock Do not use any other c...

Page 10: ...a fan failure the appropriate front panel LED is illuminated and the PDU 1209 outputs a warning alarm Up to 9 devices PDU 1209 provides power up to 9 channels DC 12 V 3 3 A NJR T01UHD NJR T01UHD PDU 1...

Page 11: ...supply Power distribution for IP NINJAR products Up to 9 independent 12 VDC and 3 3 A simultaneous outputs Overcurrent protection Others Alarm in case of excessive DC output current or cooling fan ma...

Page 12: ...evices ALARM DC12V LED Illuminates red if an overcurrent condition causes one or more output connectors to be disabled See 7 Alarm conditions ALARM FAN LED Illuminates red if the cooling fan fails to...

Page 13: ...oducts which are connected to source and sink devices Blu ray Player Blu ray Player PC for control Monitor 4K Monitor IP network 10 GbE switch Fiber optic Fiber optic Fiber optic Fiber optic PDU 1209...

Page 14: ...is powered on Do not block vent holes To provide adequate ventilation maintain sufficient clearances around the PDU 1209 30 mm 1 18 inches or more When placing the PDU 1209 in an EIA rack mount unit k...

Page 15: ...serve this precaution may result in ESD electrostatic discharge damage Turn off all devices Be sure to fully seat all plugs and connections and dress cables to reduce stress on connectors Notes If you...

Page 16: ...DU 1209 to a compatible product Insert each DC plug into an output connector until it clicks To remove a plug from the output connector grasp the plug as illustrated below Inserting Removing Grasp thi...

Page 17: ...power failure and a decrease in cooling fan speed attach the supplied 2 pin terminal block to a cable and connect to the ALARM connector AWG 28 to AWG 16 conductor gauge is recommended The maximum wi...

Page 18: ...D Power supply Problem Stop supplying Malfunction and overcurrent See 7 1 Overcurrent protection Continues to supply Failure in the fan or rotating speed slows down due to age related deterioration Se...

Page 19: ...rger current may be output Once an overcurrent condition is detected the PDU 1209 stops supplying power from the affected DC output connecter temporarily In order to notify you of the problem the PDU...

Page 20: ...n s rotational speed decreases due to age related deterioration or other causes the PDU 1209 may not operate correctly If the fan s rotational speed is insufficient to maintain the correct internal te...

Page 21: ...rt signal in case abnormality of DC output or fan is detected Connector 1 2 pin terminal block Others Power Supply AC 100V 240V 10 50 Hz 60 Hz 3 Hz Power consumption About 423 Watts Dimensions 8 27 x...

Page 22: ...ed on correctly Are cables connected correctly Are there no short circuits disconnections or loose connections Are appropriate cables for PDU 1209 being used Are there any nearby objects that may caus...

Page 23: ...06804 TEL 1 203 204 2445 Email sales idkav com URL http www idkav com Europe IDK Europe GmbH Lise Meitner Str 6 D 40878 Ratingen Email info idkav eu URL http www idkav eu Product information Support A...