Technical data
Te
chnical d
a
ta
Hygienik 2.0
Unit
2000
4)
/25
2000
4)
/35
2000
4)
/50
2000
4)
/70
Energy ef
fi
ciency class
-
1)
1)
1)
1)
Average power loss
W
164
164
164
164
Total storage tank contents
l
2000
2000
2000
2000
Storage tank contents above LSP
2)
l
700
700
700
700
Storage tank contents below LSP
l
1300
1300
1300
1300
Diameter incl. insulation
mm
1340
1340
1340
1340
Height incl. insulation
mm
2505
2505
2505
2505
Installation depth without insulation
mm
Ø 1100
Ø 1100
Ø 1100
Ø 1100
Tilted dimension of tank body
mm
2440
2440
2440
2440
Weight
kg
200
205
210
215
Single tapping volume at 45°C without LSP
2)
l
2100
2100
2100
2100
Single tapping volume at 45°C with LSP
2)
l
734
734
734
734
Tapping output
l/min
25
35
50
70
Performance index at tank temperature 52°C
-
5
9
13
15
Performance index at tank temperature 60°C
-
6
12
15
20
Performance index at tank temperature 70°C
-
8
15
20
30
Max. res. units**
-
7
14
22
33
Max. hotel rooms**
-
6
10
18
28
Max. showers at sport facilities
-
5
7
12
18
1)
In accordance with EU Ordinance 812/2013 on the energy labeling of hot water storage tanks, there is no energy labeling
for hot water storage tanks with a total volume exceeding 500 l
2)
Calculated with:
Storage temperature 60°C
Tapping temperature 45°C
Cold water temperature 15°C
3)
at a storage tank charging temperature of 70°C
4)
the Hygienik 2000 l is also available with fl ange connection as Hygienik 2000 Max 2.0, see page 16