Quantis Appliance User Manual
Document version : 2.13
Distribution : Confidential
Date : 06.08.2020
Page: 14 / 47
qa-cli>
date --set '2017-07-26 16:13:00'
Wed Jul 26 16:13:00 CEST 2017
3.2.3
Setup Network interface
The factory default configuration is:
•
Network interface LAN1
•
IPv4: 10.17.17.1
•
Netmask: 255.255.255.0
•
Gateway: 0.0.0.0
•
Network interface LAN2
•
IPv4: 10.17.17.101
•
Netmask: 255.255.255.0
•
Gateway: 0.0.0.0
This configuration should be changed to match the production LAN, in particularly new IP addresses
should be specified and separate subnets for each ethernet port should be used, if more than one
ethernet port is used in the deployment.
To change the network configuration type:
qa-cli>
nic
–
-id 1
–
-addr 10.17.17.10/8
–
-gateway 10.0.0.1
Address changed
Gateway changed
********************
GENERAL.DEVICE: eno1
GENERAL.TYPE: ethernet
GENERAL.HWADDR: 0C:C4:7A:95:88:AC
GENERAL.MTU: 1500
GENERAL.STATE: 100 (connected)
GENERAL.CONNECTION: System eno1
GENERAL.CON-PATH:
/org/freedesktop/NetworkManager/ActiveConnection/10