background image

GigE uEye SE Rev. 4

IDS Imaging Development Systems GmbH

Dimbacher Str. 6-8

D-74182 Obersulm, Germany

T: +49 7134 96196-0

E: info@ids-imaging.com

W: https://de.ids-imaging.com

Technical Manual

Summary of Contents for GigE uEye SE Rev. 4

Page 1: ...GigE uEye SE Rev 4 IDS Imaging Development Systems GmbH Dimbacher Str 6 8 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W https de ids imaging com Technical Manual...

Page 2: ...6 Mechanical specifications 11 7 Notes on PCB version 12 8 Optical specifications 15 8 1 Immersion depth for lenses 15 8 2 Position accuracy of the sensor 16 9 Electrical specifications 17 9 1 Pin ass...

Page 3: ...nor limited by the information contained in this manual Should you require further information on this product or encounter specific problems that are not discussed in sufficient detail in the manual...

Page 4: ...s This symbol indicates hints with useful information for better understanding and using features and functions This symbol indicates important warnings for product safety to prevent damage This symbo...

Page 5: ...t touch the printed circuit board while it is powered Always hold the board by the edges to avoid the risk of electrostatic discharge damage For optimum ESD behavior a clearance of 4 mm from non shiel...

Page 6: ...on de s curit LPS source puissance limit e ou ES1 PS2 Pour garantir la s curit lectrique nous recommandons l utilisation d un c ble de connexion blind ou la mise la terre du bo tier de la cam ra afin...

Page 7: ...A Information for Canada Renseignements pour le Canada CAN ICES 3 A NMB 3 A Information for UL To be compliant with the UL safety criteria GigE cameras must be operated with indoor networks only UL 6...

Page 8: ...re of the camera housing The temperature inside of the camera housing is generally higher than the outer temperature and may be up to 70 C 158 F Device temperature during operation 0 C 55 C 32 F 131 F...

Page 9: ...ock resistance of the cameras were tested as specified in EN 60068 2 6 and EN 60068 2 27 Test parameter EN 60068 2 6 Environmental testing Tests Vibration Vibration mode Sinus Lower frequency 30 Hz Up...

Page 10: ...y Therefore it is recommend connecting the cameras by a separate network card It is recommend to use Cat5e type cables The cable length of the individual segments must not exceed 100 m A segment is a...

Page 11: ...f you install or remove the camera with plugged in cables Therefore first unplug the GigE and or I O cable from the camera NOTICE Make sure to avoid mechanical or electrical damage of the printed circ...

Page 12: ...ure information Fig 2 Temperature information Mounting details The GigE uEye SE Rev 4 cameras can be mounted either using the two holes on the bottom of the front panel or via the four holes on the fr...

Page 13: ...PCB stack back on the sensor board and screw it together Fig 5 PCB version with S board The following figure shows the mounting with L board Fig 6 PCB version with L board ESD protection For optimum E...

Page 14: ...January 2020 14 Technical Manual GigE uEye SE Rev 4 Fig 7 ESD protection...

Page 15: ...deeper into the camera flange the immersion depths are specified based on the diameter named as A B and C in the image below Beside the immersion depth also the back focal length has to be considered...

Page 16: ...of the sensor 1 Fig 10 Position accuracy of the sensor 2 It cannot be guaranteed that the sensor cover glass or filter glass are absolutely parallel to each other C mount lenses can also be subject to...

Page 17: ...plant 9 1 Pin assignment GigE connector RJ45 8 pin RJ45 socket Pin Designation 100BASE TX Designation 1000BASE T Fig 11 RJ45 socket camera rear view 1 Tx Bl_DA 2 Tx Bl_DA 3 Rx Bl_DB 4 Bl_DC 5 Bl_DC 6...

Page 18: ...an external source and via Power over Ethernet PoE The camera should not be supplied through both voltage sources at once as this can irreparably damage the camera Keep in mind that a voltage drop wi...

Page 19: ...continuous IC 150 mA The digital output is galvanically isolated using an optocoupler to protect the camera and the PC against surges Only DC voltages may be applied to the digital output The output o...

Page 20: ...January 2020 20 Technical Manual GigE uEye SE Rev 4 Fig 14 Wiring of the digital output as an open collector output Fig 15 Wiring of the digital output as an open emitter output...

Page 21: ...ymbol Min Typ Max Unit IO voltage range VCCIO 0 3 3 V Input high range VIH 1 7 3 3 V Input low range VIL 0 3 0 8 V Input leakage current II A Output high range VOH 3 15 V Output low range VOL 0 2 V Ou...

Page 22: ...January 2020 22 Technical Manual GigE uEye SE Rev 4 GPIO wiring as output Fig 17 GPIO wiring as output 1 Fig 18 GPIO wiring as output 2...

Page 23: ...te information of the current status LED 1 camera status two color LED 2 Network status two color LED 1 Camera is off no power Camera is booting Camera is ready Camera is open No firmware loaded LED 2...

Page 24: ...e DL The filter type is given at the end of the model name The following table shows an overview of the different optical filters used in IDS cameras Filter type Name Refractive index nFilter Glass ty...

Page 25: ...or professional cleaning IDS Imaging Development Systems GmbH is not liable for any damage resulting from cleaning the filter glasses This even applies if the following instructions have been observed...

Page 26: ...s Only add small quantities of alcohol to the wipe Never pour alcohol directly onto the camera NOTICE Never use cleaning agents containing acetone for cleaning the filter glasses Acetone may damage th...

Page 27: ...12 PCB version 12 GPIO 21 H Housing version 11 I I O connector 17 Immersion depth lens 15 Immunity 7 Infrared cut filter 24 Input digital 18 L Linux 10 N Network cable 10 card 10 Network adapter 10 O...

Reviews: