Section: 9
IDS X64 LCD Keypad User Manual 700-411-01C Issued August 2010
24
profile 2 by holding the
[5]
key for two seconds. STAY and BUZZ zones can be programmed for each
profile once the profile has been selected. See sections 9 & 10.
9.1
How to Select a Stay Profile
[MODE] [2] [*] [PROFILE NUMBER] [*]
1.
Hold
[MODE]
down for one second until the keypad beeps twice.
2.
The LCD display reads „Mode *‟.
3.
Press the
[2]
key followed by the
[
*
]
key.
4.
The LCD display reads „P *‟.
5.
Press
[1]
,
[2]
,
[3]
, or
[4]
for the required profile, followed by the
[*]
key.
6.
The buzzer will give a long beep.
7.
Program STAY and BUZZ zones for the profile or ARM the profile (See sections 9 & 10).
9.2
How to Program / Cancel Stay Zones
[3] [ZONE NUMBER] [*] [#]
1.
Select the required stay profile (See section 9.1)
2.
Hold down the
[3]
key until the keypad buzzer sounds.
3.
The LCD display read „Zone *.‟
4.
Press the
[ZONE NUMBER]
corresponding to the zone you wish to be a Stay zone followed by
the
[
*
]
key. Alternatively use the
[PANIC]
or
[MED]
keys to scroll through the zones.
5.
A
[Y]
next to a zone number indicates that that particular zone is programmed as a stay zone.
6.
Press the
[*]
key to toggle between YES and NO.
NOTE:
Buzz zones will be shown by flashing LEDs. (See Section 10). A Buzz zone cannot be selected
as a Stay Zone. The Buzz status must be cleared first.
7.
Repeat steps 4 - 6 until the all the required Stay zones are programmed/cancelled..
8.
Press the
[#]
key to exit the Stay zone programming mode.
10.
Buzz Zones
Violation of a buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30
seconds during which time a valid user code must be entered. If a valid user code is not entered during
this period, the system will register an alarm condition. This feature helps prevent unnecessary false
alarms.
NOTE:
If an Entry/Exit zone is programmed as a buzz zone, violation of the Entry/Exit zone (when the panel is
Stay Armed) will cause the keypad buzzer to sound for the duration of the entry delay time. This, if the
panel is stay armed, allows the user to enter the premises and disarm the panel.
If it is not programmed as a buzz zone, the alarm will be triggered immediately. If the panel was armed
using the
[6]
key (Stay Arm and Go) violation of the Entry/Exit zone will always start the Entry/Exit delay.
Summary of Contents for X64
Page 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...
Page 2: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 2...
Page 5: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 5...
Page 6: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 6...
Page 28: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 28...
Page 29: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 29...
Page 30: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 30...
Page 32: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 32...