Electrical Installation
:
Good grounding:
IDT processors are CEM certified guaranteeing that the
equipment can function in an electro-static environment. The key is to make sure
that the equipment is properly grounded as results please fix all 4 screws of the
front panel to the rack to allow. All IDT processors also have a ground connector
at the rear of the unit which allows a connection to the rack.
NB : don’t forget to connect the ground link of the rear panel to the rack!
The right fuses :
The fuses in the power supply are, standard, 2AT 250V. In
case of use on a 115 Vac. network they should ideally be changed for 4AT 250V.
The equipment needs an AC power supply of 115 Vac or 230 Vac 50/60Hz and
must be properly earthed. There is an earth screw on the equipment for that
purpose. Should the equipment not be in use for a certain period it should be
unplugged.
.
The right Cable :
IDT are supplied with standard IEC AC cables. The cables are
French standard. This cable should be changed to respect the electrical standards
of your country. IDT Sound Processing Corporation cannot guarantee any
breakdowns should a non-standard cable be used.