15. AC Timing
400
PowerSpan II User Manual
80A1010_MA001_09
Integrated Device Technology
www.idt.com
The PowerSpan II PB Interface can be configured for 100 MHz operating frequencies.
summarizes the timing behavior of a PowerSpan II PB interface configured for 100 MHz.
1.
Numbers measured into lumped 35 pF load.
2.
The transaction parameter group of signals includes: PB_A[0:31], PB_AP[0:3], PB_TSIZ[0:3], PB_TT[0:4], PB_TBST_, PB_GBL_, PB_CI_,
PB_D[0:63], PB_DP[0:7].
3.
The transaction control group of signals includes: PB_TS_, PB_ABB_, PB_DBB_, PB_TA_, PB_DVA_L, PB_TEA_, PB_AACK_.
4.
The transaction arbitration group outputs includes: PB_BR[1]_, PB_BG[1:3]_, PB_DBG[1:3]_
5.
The point to point signals include: PB_BG[1]_, PB_BR[1:3]_, PB_DBG[1]_
Table 100: PB Timing Parameters
Timing
Parameter
Description
CE/IE
Units
Note
Min
Max
t
302
PB_CLK to output valid delay
Parameter group outputs
1.0
5.0
ns
1,2
Control group outputs
1.0
5.0
ns
1,3
PB_ARTRY_
1.0
5.0
ns
1
Arbitration group outputs
1.0
5.0
ns
1, 4
t
303
Input setup time
Bussed signals
3.0
ns
PB_AP
2.0
ns
Point to point signals
3.0
ns
5
t
304
Input hold time
0.3
ns