Page | 32
Response Example
STX
Len
Low
Len
High
Response Body
LRC
CHK
SUM
ETX
02
25
00
06 <Firmware Version String>
3A
74
03
Return Hex String:
022500064944205445434820536d61727450494e204c313030204669726d776172652056312 e30303a7403
<STX> <length byte low><length byte high> <ACK>ID TECH SmartPIN L100 Firmware V1.00 <LRC><SUM> <ETX>
8.8.2
Get Internal Firmware Version
Command Body:
78 31
Response Example
STX
Len
Low
Len
High
Response Body
LRC
CHK
SUM
ETX
02
25
00
06 <Firmware Version Number>
Return Hex String:
Response Body:
06 + K21Version 0x0D + MAXQ firmware version
8.8.3
Enter into Bootloader
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
03
00
78 46 7A 49 52 46 57 00 00 00 00 00 00 00
00
4E
70
03
Output Hex String:
Command Body:
78 46 7A 49 52 46 57
Response Body:
06 – Device has the function, or
15 – Device does not have the function.
8.8.4
Get Serial Number
Command Body:
78 46 02
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
03
00
78 46 01
3C
C0
03
Output Hex String: 0203007846023cc003
Response Body:
06 + 10 bytes ASCII code Serial Number Or 15 62 00 – No Serial Number
Response Example