7.8.
Contact Set ICS Identification (60-16)
The
Contact Set ICS Identification
command sets the reader’s ICS terminal configuration number
(Contact Command EMV L2 includes 4 approved configurations of certification: 1C, 2C, 3C, or 4C).
This command affects the
Contact Set Terminal Data (60-06)
command. Generally, readers call 60-
16 first, then 60-06.
Examples:
Set 3C configuration:
5669564f746563683200601600010392ed
Reader responds with:
5669564f746563683200600000003d35
(Success)
Now set terminal data (TLVs) with config values appropriate to 3C:
5669564f746563683200600600c818005f3601029f1a0208409f3501259f330360d8
c89f40056000f050019f1e085465726d696e616c9f150212349f160f303030303030
3030303030303030309f1c0838373635343332319f4e2231303732312057616c6b65
722053742e20437970726573732c204341202c5553412edf260101df1008656e6672
65737a68df110101df270100dfee150101dfee160100dfee170107dfee180180dfee
1e08f0dc24f0c20e1400dfee1f0180dfee1b083030303135313030dfee20013cdfee
21010adfee2203323c3caa88
Reader responds with:
5669564f746563683200600000003d35
(Success)
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n
Byte 15+n
Header Tag &
Protocol
Version
Command
Sub-
Command
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (LSB)
CRC (MSB)
ViVOtech2\0
60h
16h
00h
01h
ICS
Identification
ICS Identification:
0x01
→
Identification 1C
0x02
→
Identification 2C (Default)
0x03
→
Identification 3C
0x04
→
Identification 4C
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n
Byte 15+n
Header Tag &
Protocol
Version
Command
Status Code
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (MSB)
CRC
(LSB)
ViVOtech2\0
60h
See Status
Code Table
00
00