background image

 

20060201                                                         MAML200HE01 

Quick Installation Guide 

Proximity Access Controller 

 

 

1.1 Confirming a power supply 

                Before wiring, confirm DC 12V and 150mA which are inputted into IP-RFL200. 

1.2 Wiring 

 

 

 

 

 

 

 

 

 

 

 

 

 

※  Caution: Select lock type as shown below. 

9

 

Power Fail Safe Mode (Always open at power off) 

: Connect lock type of yellow with black (GND) wire. 

9

 

Power Fail Secure Mode (Always close at power off)   

: Disconnect lock type of yellow wire.   

 

 

 

2.1 Supplying a power 

Supplying a power, all LEDs are on with red or green color.   

After above state repeat ON/OFF two times, red LEDs at OFF state are on orderly.   

At this time, IP-RFL200 sounds beeper one time. 

 

2.2 Reading a registered card 

When being read a registered card, all LEDs change from red to  green. And then they 

are off and on orderly. During five seconds, door lock is open. 

At this time, IP-RFL200 sounds beeper one time. 

 

2.3 Reading a unregistered card 

When being read a unregistered card, all red LEDs repeat on and off in twice. 

At this time, IP-RFL200 sounds beeper two times. 

1. Installation Environment 

2. Operation 

Reviews: