APPENDIX
p.43
Parity bit : NONE
Data bit : 8bit
Stop bit : 1bit
In case of using TCP/IP Communication
- Check IP, Subnet Mask, Gateway and Port setting value.
- Check more information about above setting value using the software m
anual.
2. Check the line connection for communication.
In case of RS232
- Check the RS232 Serial Jack Cable is correctly connected.
In case of RS485
- When a multi-drop communication doesn’t work, test one-by-one
Communication from first.
In case of TCP/IP Communication
- Check the LED is flickering on the back of the product.
- If it is flickered, check the cable connection.
3. If the trouble remains after the procedure above, contact a designated s
ervice center.