User Manual 

 

9. Wire Connection to Controller 

 

 

 
 

                                                                                      NEO RF245 Wire Connection 
 

# Notice 

-

 

Connect  both  yellow  (OTR,  one  time  reading)  and  white  (WIEGAND-1)  cable  to  the  ON/OFF  switch  (the  switch 
must be ON when setting up reading range). 

-

 

Turn ON the switch when setting up reading range. Make sure to turn it OFF after a desired range is setup. 

Summary of Contents for NEO RF245

Page 1: ...1 December 2016 Copyright IDTECK Co Ltd User Manual NEO RF245 LONG RANGE READER ...

Page 2: ...RE 4 4 SPECIFICATION 5 5 IDENTIFYING SUPPLIED PARTS 6 6 INSTALLATION OF THE PRODUCT 7 7 CABLE COLOR 10 8 OUTPUT FORMAT AND TIMING 11 9 WIRE CONNECTION TO CONTROLLER 12 10 OPERATION 13 11 FCC REGISTRATION INFORMATION 17 12 WARRANTY POLICY AND LIMITATION OF LIABILITY 18 13 HOW TO MAKE RMA REQUEST AFTER SALES SERVICE 19 ...

Page 3: ...emperature over 60 C low temperature Below 35 C or high humidity Do not operate the product with the tool in hand when power is on Do not drop objects on the product or apply strong blows to it Keep away from magnetic interference Keep out of direct sunlight and heat radiation sources If you want to relocate the already installed product be sure to turn off the power and then move or re install Do...

Page 4: ... it sets channel and site code automatically User can check operation status by internal buzzer red and green LED 3 Feature Long range reader NEO RF245 IDA245 N IDA245 N H2 Active card is used 2 45GHz frequency Encrypted Tag ID and Secure Protocols between Reader and Tags Multiple Tags Reading 30 Tags Sec 90 One Directional Antenna Option 360 Omni Directional Antenna 26bit Wiegand and RS232 Output...

Page 5: ...50mA Output Format 26bit Wiegand and RS232 Bargate Output RS232 Format 9600bps parity none 8 Data bits 1 Stop bit Bargate Output 1A Power Transistor 1s OTR One Time Reading Control Input Low Active Input DC12V Max 50mA Current Drain HOLD Control Input Low Active Input DC12V Max 50mA Current Drain Vehicle Detector Input LED Indicator Built in Red Green LED Beeper Built in Piezo Buzzer Operating Tem...

Page 6: ...td User Manual 5 Identifying Supplied Parts Unpack and check the contents If any of these parts are missing contact your distributor NEO RF245 Quick Installation Guide Mounting Bolts Mounting Bracket ON OFF Switch for Reading range setting ...

Page 7: ...7 December 2016 Copyright IDTECK Co Ltd User Manual 6 Installation of the Product ...

Page 8: ... loop coil and speed bump are extra purchase IDTECK doesn t offer these contents Reading Angle of NEO RF245 The reading angle of RF245 is approximately 90 degree at the front side of the reader However the reader has about 10 of the maximum reading distance at the rear side of the reader ...

Page 9: ...when installing multiple RF245 ex F 1 3m F 2 5m at least 2 In case of not being able to keep enough distance between two or more readers due to the spatial constraints a user can set desire reading range by adjusting the angle If it is difficult to have enough space between the NEO RF245 due to the spatial constraints 3 Using a reader hood will diminish the reading range therefore set a speed bump...

Page 10: ...t drain rate is 1 Amps 2 HOLD input is used to force NEO RF245 to read a tag when loop sensor detects any approaching vehicle When a vehicle is detected NC contact should be used and the input should also be disconnected from GND completely In OTR mode the reader will only output tag ID 1 time CAUTION Nothing should be connected to this input unless loop sensor is in use 3 OTR cable yellow is used...

Page 11: ... low active pulse Interval between bits 1ms 8 2 RS232 output format Baud Rate 9600bps Parity None Data bit 8 Stop bit 1 LRC Exclusive OR XOR from Start 0x02h to End 0x03h Start 0x02h Card ID 8 ASCII char End 0x03h LRC XOR total 11 bytes 8 3 Bargate output Timing Low active pulse 1 sec duration Transistor open collector output ...

Page 12: ...ller NEO RF245 Wire Connection Notice Connect both yellow OTR one time reading and white WIEGAND 1 cable to the ON OFF switch the switch must be ON when setting up reading range Turn ON the switch when setting up reading range Make sure to turn it OFF after a desired range is setup ...

Page 13: ... BARGATE output is a transistor open collector output with the maximum current drain of 1 A 10 4 One time reading OTR control Input Connect OTR yellow cable to GND to activate One Time Reading mode During this state the reader will only generate output signal when a tag is detected for the first time If a user needs to scan the same tag again the particular tag must be completely out of the readin...

Page 14: ... the users can freely set the reading range at the desired distance 10 6 Power off NEO RF245 10 7 Connect yellow OTR one time reading and white Wiegand_D1 cables together You can use a enclosed switch to connect two cables together as shown below The switch must be turned on before setting up reading range Make sure to turn off when finished ...

Page 15: ...n The tag should be scanned 10 straight times For the first 5 times of the scanning a single sound Bee will be generated From the 6th to 9th times of scanning double sound Bee Beep will be generated At the last 10th time of scanning triple sound Bee Bee Beep will be generated Now the distance of that 10th time of scanning will be programmed as a new reading distance When finished the reading range...

Page 16: ...ge is 2 meters and you want to maximize the reading range How 1 Follow the steps above 5 6 and 5 7 2 Wait until green LED turns off DO NOT scan any tag until it fully goes off 3 Follow the steps 5 9 to 5 10 Recognition distance shall be set with the maximum reading range Note 1 Reading range can have a margin of error that depends on installation circumstances 2 The default reading range of NEO RF...

Page 17: ...ass A Digital Device pursuant to Part 15 of the FCC rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ha...

Page 18: ...rranties obligations or liabilities on the part of IDTECK and IDTECK DISCLAIMS ANY AND ALL WARRANTY WHETHER EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to p...

Page 19: ...to IDTECK RMA Center Product without RM A Code is not accepted If you have any questions or problems regarding the RMA services please contact us using the contact information below Friendly representatives at IDTECK are always standing by to provide the best after sales services IDTECK Headquarter 5F Ace Techno Tower B D 468 Gangseo ro Gangseo Gu Seoul 07573 Korea Tel 82 2 2659 0055 Fax 82 2 2659...

Page 20: ...er Manual The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 468 Gangseo ro Gangseo Gu Seoul 07573 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...