15
12-15. Add User Access Card/PIN (RF/PIN Combination Mode)
……
or or ……..
Configuration Card Command PIN PIN Configuration Card
<TABLE 1> SETTINGS FOR COMMAND
Symbol
Setting Values
Examples/Remarks
Output
Mode
(OM)
(You must add value
①
and
②
)
Setting value for activating time
①
Activate Mode
Value
Activate only in Secure Mode
:
00
Activate in Safe & Secure Mode
:
50
Setting Value for activating Output Port
②
Activate Output Port
Value
Activate only Door Relay
:
01
Activate only Alarm Relay
:
02
Activate only TTL Output
:
04
Activate Door Relay & TTL
:
05
Activate Alarm Relay & TTL
:
06
EX1)Activate Door Relay
In Safe & Secure Mode
①
Safe & Secure Mode
50
②
Door Relay
01
OM =
51
EX2)Activate Alarm Relay
& TTL only in Secure mode
①
Secure Mode
00
②
Alarm Relay & TTL
06
OM =
06
tt
tt
is the activating time value (seconds) from 01sec. to 99sec.
tt
value 00sec. means no operation.
PW
PW is the 2 digit Password for Duress Alarm.
Do not use ‘77’ for PW as it is used for Secure Mode
mm
mm
is the activating time value (minutes) from 01min. to 99min.
mm
value 00min. means no operation.
12-21. Change Door Open Time When User Access Card (or PIN) is Granted
(
tt
=00~99 sec., Default Door Open time = 03 sec.
)
Configuration Card Command Door open time TTL time
/Configuration PIN
12-22. Change Alarm Time When User Access Card (or PIN) is Denied
(Refer to Table 1 for OM,
tt
=00~99 sec., Default Alarm time = 02 sec.
)
Configuration Card
Command Output Mode Door time Alarm Time TTL time
/Configuration PIN