background image

 
 
                                                                                                                 

   

 

  9       

User’s Manual 

 

10. FCC Registration Information 

 

FCC REQUIREMENTS PART 15 

 

Caution: 

Any changes or modifications in construction of this device which are not expressly 

approved by the responsible for compliance could void the user's authority to operate the equipment

 

NOTE: 

This device complies with 

Part 15 of the FCC Rules

 

Operation is subject to the following two conditions; 

1. This device may not cause harmful interface, and 

2. This device must accept any interference received, including interference that may cause 

undesired operation. 

 

This equipment has been tested and found to comply with the limits for a 

Class A Digital Device

pursuant 

to Part 15 of the FCC Rules

. These limits are designed to this equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined 

by turning the radio or television off and on, the user is encouraged to try to correct interference by 

one or more of the following measures. 

 

1. Reorient or relocate the receiving antenna. 

2. Increase the separation between the equipment and receiver. 

3. Connect the equipment into an outlet on another circuit. 

4. Consult the dealer or an experienced radio/TV technician for help. 

Summary of Contents for Star RF10

Page 1: ...User s Manual Proximity Card Reader ...

Page 2: ...4 Specification 6 5 Identifying Supplied Parts 6 6 Installation 7 7 Wire Color Table of the RF 10 RF 20 7 8 Wire Connection to Access Controller 8 9 Operation 8 10 FCC Registration Information 9 11 Warranty Policy and Limitation of Liability 10 12 How to Make RMA Request After Sales Service 11 ...

Page 3: ...nd temperature specified in the specification Do not install the product with tools such as driver in hand when power is being supplied Do not drop liquid onto the product such as water and give the product a severe shock Do not place magnetic objects near the product Do not replace the wiring cables installed by experts Do not use the product under direct sunlight or in a heat producing place suc...

Page 4: ...ation IDTECK Format Read Range Up to 4 inches 10cm In case of IDC170 User Format Available Output Format 26bit Wiegand default RS232 Optional Simultaneous output of 26bit Wiegand and RS232 Easy to Install on Metal Door Frame or Mullion or Wall Mount LED Control Port and Buzzer Control Port Solid Epoxy Potted Waterproof Dustproof IP65 IP66 Lifetime warranty Reverse Polarity Protection Compatible Co...

Page 5: ...Red and Green Piezo Buzzer Operating Temperature 35 to 65 C 31 to 149 F Operating Humidity 10 to 90 relative humidity non condensing Color Material Dark Pearl Gray Polycarbonate Weight Dimension W x H x T 133 5g 0 296lbs 45 5mm x 124mm x 24mm 1 79 x 4 76 x 0 91 143g 0 32lbs 75 5mm x 124mm x 24mm 2 97 x 4 88 x 0 94 Waterproof Dustproof IP65 IP66 Certification FCC CE KCC MIC 5 Identifying Supplied P...

Page 6: ...les 6 2 Pass the reader cable through the center hole and install the reader module by using two 3 5 40 or 3 5 25 screws 6 3 Put bezel on the reader module and push bezel 7 Wire Color Table of the RF 10 RF 20 SIGNAL COLOR Main Power 12V Red Power Ground GND Black Not Connect Orange Wiegand Data 0 Out Green Wiegand Data 1 Out White Buzzer Control In Blue LED Control In Yellow RS232 TX Brown Please ...

Page 7: ...color setting oppositely by connecting LED Control Input wire Yellow wire to Power GND In this case Green light is turned on when the reader is on standby and once you present RF card the LED of RF10 20 turns into red simultaneously And then it turns into green again for next reading 9 4 Buzzer Control If Buzzer Control Input wire Blue wire is connected to Power GND buzzer generates sound continuo...

Page 8: ...e pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference ...

Page 9: ...PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NO...

Page 10: ...MA Center Product without RMA Code is not accepted If you have any questions or problems regarding the RMA services please contact us using the contact information below Friendly representatives at IDTECK are always standing by to provide the best after sales services IDTECK Headquarter 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 008...

Page 11: ...12 User s Manual MEMO ...

Page 12: ...d User s Manual The specifications contained in this manual are subject to change without notice 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...

Reviews: