ID GATE 7700
Product Instruction
ID GATE 7700
Page 13 of 15
4. Menu Parameter Setting
4.1 Button introduction
Control board:
“ENT”, “INC”, “ESC”, and “DEC”
ENT:
Enter ENT setting or to determine the current modified value
ESC:
Back to previous menu
4.2. Menu setting
Step1:
Press “ENT “for 3s to enter, press “INC”, “DEC” to choose F01 menu list
Step 2:
Press “ENT” to enter the time setting
Step 3:
Press “INC”, “DEC “to set the numbers
Step 4:
After finish setting, press “ENT “to save
Step 5:
Press “ENT”, it will asthmatically quit from main menu
4.3. Parameter setting instruction
Control board connected to power, LED display shows <Run>
[F 0 1]
Set the passage time: Within this time, pedestrian can pass the gate. If no pedestrian pass, the gate will close
asthmatically after times up( default time is 5 seconds
)
[F 0 2]
Access is permitted and prohibited: 0: R&L all prohibited 1: All permitted 2:Left prohibited, right permitted 3: Right
prohibited, left permitted. (default is 0
)
[F 0 3]
Turnstile working mode: 0: Free passage 1: Arm down when power off (default 1)
[F 0 4]
Memory function: When open or close the entrance gate, if there is memory function, normally sued when one
pedestrian swipe the card but without permitted pass, the gate can save other pedestrians’ cards information.
Prohibited: 00 - when the first pedestrian swipe care and pass the second pedestrian need to swipe card too.
Permitted: 01- means the number of people allowed to swipe is the number of people allowed to pass in succession.
Permitted “means whoever swipes a valid card then they are allowed to pass (default is prohibited: 00)
[F 0 5]
Repeatedly open and close the switch testing: It is mainly used for testing the stability and aging of brake control
panel. Note: in test mode, press the ESC key to exit the test.
[F 0 6]
Zero signal setting: 0: close the gate/ channel immediately if the zero signal is detected (tripod turnstile standard
mode, the main board is set to 0 by default) 1: zero signals are detected, and then the gate is closed after waiting for the
zero signals to disappear (commonly used at full height turnstile).
[F 0 7]
Normally open setting of turnstile: This parameter is used to detect the continuous opening signal. When the
continuous opening signal exceeds the set parameter, the system enters the normally open state. If it is a continuous
signal, the gate will always be open. After the continuous signal is disconnected, the gate will resume the standard mode.
(The default parameter is 6 seconds, that is, press the "left open" or "tight open for more than 6 seconds, the gate is
normally open, release the "open" button, and the gate is restored.)
[F 0 8]
Opening time delay: This parameter can only be effective when the memory function is turned on. After the
memory function is turned on, the time delay of opening the gate for more than one person can be prevented from
opening the gate again when the previous person has not passed the channel.
[F 0 9]
Back to factory settings: All main board parameters are restored to factory settings.
Summary of Contents for ID GATE 7700
Page 1: ...Tripod Turnstile ID GATE 7700 User Manual...
Page 10: ...Product Instruction Communication Protocol Page 10 of 15 ID GATE 7700...
Page 11: ...ID GATE 7700 Product Instruction ID GATE 7700 Page 11 of 15...
Page 12: ...Product Instruction Communication Protocol Page 12 of 15 ID GATE 7700...