background image

ID GATE 7700 

 

Product Instruction 

ID GATE 7700 

 

Page 9 of 15 

 

3. Install Instruction 

 

3.1 Installation note & suggestion 

 
Note: During installation and construction, relevant circuits should be disconnected to ensure that all circuits are correct 
before energizing.  
 
 

►►

Installation Suggestion: 

 
1) For cables, suggest laid 60mm deep, over 50mm, and connector area be bending to avoid water.  
 
2) If the turnstiles install in the outside, suggest installed in concrete deep 100-200mm to avoid natural damaged.  
 
3) All the operation should be done when power off.  
 
4) Wear the strong electric cable and the weak electric cable are respectively with 3/4 "PVC pipe and buried to the 
corresponding position with cement.  
 
5) After adjusting the foundation surface, arrange the equipment in good order. 
 
6) After the hole location is determined, drill the hole and embed the anchor bolt or expansion bolt of M12.  
 
7) Open the case, select one of the equipment as the reference (preferably choose the middle one as the reference), align 
the base bolt hole with the corresponding anchor bolt, and pre-tighten the nut.  
 
8) Connect the power line and control line according to the wiring diagram, and connect the system protection ground wire.  
 
9) Check the mains wiring according to the wiring diagram, check the power wiring and other wiring of the whole equipment 
are correct, and the power can be adjusted after confirmation.  
 
10) After completion of the installation, check the connection condition of earth wire, connector assembly for connecting 
line and all moving parts with the device. Make sure the connection is firm in order to prevent failure caused by long time 
operation. If any screw or part is not tightened, please tighten.  
 
11) After the equipment status check is normal, the following functions can be debugged. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ID GATE 7700

Page 1: ...Tripod Turnstile ID GATE 7700 User Manual...

Page 2: ...IC GmbH Ludwig Reichling Stra e 4 67059 Ludwigshafen Germany Deutschland Phone 49 621 6690094 0 Fax 49 621 6690094 9 E Mail info idtronic de Web idtronic de Issue 4 63 23 January 2023 Subject to alter...

Page 3: ...1 Tripod 5 2 1 Tripod turstile electric control system 5 6 2 1 Operating priciple of the system 7 3 Install Instruction 8 3 1 Installtion note suggestion 8 9 3 2 Turnstile cable drawing 10 3 3 Operati...

Page 4: ...ith any type of the third party access control parts e g RFID Fingerprint and Biometric reader device o Unified external electrical interface which can be linked to a variety of card readers and can b...

Page 5: ...in figure 1 Figure 1 1 3 Technical parameter Item Description Cabinet 304 stainless steel Dimension L1200 W230 H980 mm Weight 50Kg Pass Width 1 lane 550mm Arm length 500mm Power supply AC220V 110V 50...

Page 6: ...posed of card reader main control board infrared sensor direction indicator board alarm and transformer and so on o Card reader self provided after reading the information on the card and judging and...

Page 7: ...onal 2 Control board The control center of the system which receives signals from the card reader and infrared sensor and makes logical judgment and processing of these signals and then sends out exec...

Page 8: ...the direction indicator and motor so that the direction indicator sign turns into the green arrow pass sign At the same time the turnstile sends the setting voice the main control board controls the...

Page 9: ...location is determined drill the hole and embed the anchor bolt or expansion bolt of M12 7 Open the case select one of the equipment as the reference preferably choose the middle one as the reference...

Page 10: ...Product Instruction Communication Protocol Page 10 of 15 ID GATE 7700...

Page 11: ...ID GATE 7700 Product Instruction ID GATE 7700 Page 11 of 15...

Page 12: ...Product Instruction Communication Protocol Page 12 of 15 ID GATE 7700...

Page 13: ...allowed to swipe is the number of people allowed to pass in succession Permitted means whoever swipes a valid card then they are allowed to pass default is prohibited 00 F 0 5 Repeatedly open and clo...

Page 14: ...r there is 24V voltage output at the solenoid valve terminal of the main board and judge whether the solenoid valve is damaged B Tripod turnstile arms won t fall down when power off a check if the ele...

Page 15: ...ion ID GATE 7700 Page 15 of 15 6 Customer Service We are very happy to help you in the future when you encounter problems or product defects if the use or operation is not clear please timely contact...

Reviews:

Related manuals for ID GATE 7700