background image

Mode specification 

 

Instruction Manual 

Page 4 of 7 

 

RFID Devices 

1

 

Mode specification 

Setting mode: Press button 3 

1.1

 

Fixed private mode 

A

fter sound “di”, lock bolt stick

 out. 

Read the card →motor rotate, lock open →after 3s, lock bolt stick out, lock close

 

1.2

 

Temporary public mode 

A

fter sound “di, di”, the lock bolt retract

s. 

 

It keeps unlock before read any temporary card.

 

 

Users can swiping any card to lock, and use the same card to open.

 

1.3

 

Fixed public mode 

A

fter sound “di, di, di”, the lock bolt stick out.

 

 

It keeps lock before read card.

 

 

After change to fixed public mode, need to set fixed card through manage card.

 

 

After set fixed card, swiping card to open lock, the lock bolt will keep retracted.

 

 

Swiping the fixed card to close the lock.

 

1.4

 

Random public mode (factory default) 

 

Before setting mode, user can use any card to close the lock, and need use the same card to open the lock.

 

 

After setting mode and setting manage card, change to temporary public mode.

 

2

 

Introduction of Function Buttons 

2.1

 

Button 1: Set manage card 

Press button 1 for 2s

, the lock issue a short “di”,

 then enter into card configuration, swiping one card to be manage card. 

 

After long sound “di”, the green light will flash, it means setting the card successfully.

 

 

After two short sound “di, di”, the red light will flash, it means setting the card unsuccessfully.

 

 

Can only set one card to be managing card.

 

 

The manage card can only be used to set card but cannot be used to open the lock (Only temporary public mode 
can open the lock).

 

Remark: Set user card (only Fixed private mode & Fixed public mode) 

 

Swiping  manage  card,  the  lock  issue  “di”,  then  enter  into  card  configuration,  the  green  light  will  flash  ,  then 
swiping one card to be user card.

 

 

After sound “di”, it means setting the user card successfully.

 

 

Can set user card continuously as long as the green light flash.

 

Each lock can accept 50pcs card at most. 

2.2

 

Button 2: Set delete card 

 

Press button 2 for 2s, the lock issue a short “di” and enter into setting card, swiping one card to be delete card.

 

 

Delete card can delete all users cards at one-time but cannot delete the manage card.

 

 

Delete card cannot be used to open the lock.

 

Summary of Contents for ID Lock 1000

Page 1: ...ID Lock 1000 13 56 MHz RFID Device Instruction Manual ...

Page 2: ...DTRONIC GmbH Donnersbergweg 1 67059 Ludwigshafen Germany Deutschland Phone 49 621 6690094 0 Fax 49 621 6690094 9 E Mail info idtronic de Web idtronic de Issue 0 1 25 June 2018 Subject to alteration without prior notice Copyright iDTRONIC GmbH 2018 Printed in Germany ...

Page 3: ...tory default 4 2 Introduction of Function Buttons 4 2 1 Button 1 Set manage card 4 2 2 Button 2 Set delete card 4 2 3 Button 3 Change mode 5 2 4 Button 4 Set single double card mode 5 3 Sound Prompt Function 5 3 1 Card read prompt 5 3 2 Unlock Lock 5 3 3 Warning 5 4 Security Function 5 4 1 Locking of illegal card 5 4 2 Low voltage alarm 5 4 3 Power saving 5 5 Installation 6 6 Technical Data 7 ...

Page 4: ...tion of Function Buttons 2 1 Button 1 Set manage card Press button 1 for 2s the lock issue a short di then enter into card configuration swiping one card to be manage card After long sound di the green light will flash it means setting the card successfully After two short sound di di the red light will flash it means setting the card unsuccessfully Can only set one card to be managing card The ma...

Page 5: ...states the lock will issue sound as di di di di di di or a long di 3 2 Unlock Lock After read the card successfully the motor will rotating back and forth the lock will issue sound di 3 3 Warning Can set warning tone if the door keeps open for long time User can require the time setting when manufacture For example if the door is not closed for more than 30 seconds the buzzer will issue an on goin...

Page 6: ...Installation Instruction Manual Page 6 of 7 RFID Devices 5 Installation Drawer Ordinary cabinet door Sliding cabinet door ...

Page 7: ...ock hook Battery DC 6V 4 1 5V AAA size Driven mode Motor servo Static power consumption 70 µA Dynamic power consumption 200 mA Warning voltage 4 5 V Unlock way RFID card 13 56 Mhz Response time Less than 500 ms Working temperature 15 55 C Working humidity 5 95 RH Working life Standby mode 1 year Test Salt spray testing 72 hours Application Dormitory storage locker gym cabinet swimming pool storage...