Sound Prompt Function
HF RFID Reader
Page 5 of 7
2.3
Button 3: Change mode
•
Factory mode: Random public mode .
•
Press button 3, the lock issue a short “di” and enter into fixed private mode.
•
Press button 3, the lock issue short “di, di” and enter into temporary public mode.
•
Press button 3, the lock issue short “di, di, di” and enter into fixed public mode.
2.4
Button 4: Set single/double card mode
•
Press button 4, the lock issue a short “di” and enter into single card mode. Under this mode, can only set user
card.
•
Press button 4, the lock issue short “di, di” and enter into double card mode. Under this mode, can set user card
+ staff card at the same time.
Notes:
•
After change mode, user cards and staff cards will be invalid. But manage card and delete card are still valid.
•
Press button “Reset”, the lock issue short “di, di, di” and will be initialized. All cards will be invalid and lock system
will be back to random public mode.
3
Sound Prompt Function
3.1
Card read prompt
According to different functions or states, the lock will issue sound as:
“di”, “di, di”, “di, di, di” or a long “di”.
3.2
Unlock/Lock
After read the card successfully, the motor will rotating back and forth, the lock will issue sound
“
di
”
3.3
Warning
Can set warning tone if the door keeps open for long time .(User can require the time setting when manufacture).For
example , if the door is not closed for more than 30 seconds, the buzzer will issue an on-
going long “di” to
remind user that
the door is not closed (This function can be only used in private mode.)
User can press button 1 and button 2 at the same time to choose whether need warning function or not.
4
Security Function
4.1
Locking of illegal card
•
If read the lock with illegal card for 5 times, the system will be locked and use the correct card can read or set.
•
In locking condition, if read any card, it will issue "di di di di di" as the alarm sound.
4.2
Low voltage alarm
•
4.5V ±0.1V. If read card, the lock will issue “di di di” as the alarm sound.
•
4.0V±0.1V. After unlock for the last time, the motor stops working. The lock is open and cannot be closed any
more. User need to change the battery.
4.3
Power saving
If there is no any operation, lock system will enter into sleeping mode after 3seconds.