ID GATE 6000 Electromechanical Tripod Turnstile
29
APPENDIX 1. Control signal algorithm at pulse control mode
Note:
For the RC panel:
•
active front
—
pressing of the relevant button on the RC panel;
•
low level
—
the relevant button on the RC panel has been pressed;
•
high level
—
the relevant button on the RC panel has not been pressed.
The command is a signal active front (signal transfer from the high level to the low level) at
any of the contacts at presence of the corresponding signal levels at the other contacts.
The following commands can be formed by sending a low-level signal to the contacts
“
Unlock A
”,
“
Stop
”
and
“
Unlock B
”
of the
XT1.L
connector block relatively to the contact
“
GND
”:
Always locked (locked for entry and exit)
Active front is at the contact
“
Stop
”
while there is a high level at the contacts
“
Unlock A
”
and
“
Unlock B
”.
Both passage directions are locked at this command.
Single passage in the direction A (open for passage of one person
in the direction A)
Active front is at the contact
“
Unlock A
”
while there is a high level at the contacts
“
Stop
”
and
“
Unlock B
”.
At this command the passage direction A opens either for 5 sec. or until the passage has
been made in this direction or until the command
«Always locked»
, and the status of the
passage direction B does not change at that. The command is ignored if
at the moment of its receipt the status of the passage direction A is
«Always free»
.
Single passage in the direction B (open for passage of one person
in the direction B)
Active front is at the contact
“
Unlock B
”
while there is a high level at the contacts
“
Stop
”
and
“
Unlock A
”.
At this command the passage direction B opens either for 5 sec. or until the passage has
been effected in this direction or until the command «Always locked», and the status of the
passage direction A does not change. The command is ignored if at the moment of its
receipt the status of passage direction B is «Always free».
Bi-directional single passage (open in both directions
for ‘one
-by-
one’
passage)
Active front is at the contact
“
Unlock A
”
while there is a low level at the contact
“
Unlock B
”
and a high level at the contact
“
Stop
”,
or active front is at the contact
“
Unlock B
”
while there is a low level at the contact
“
Unlock A
” and a high level at
the contact “
Stop
”.
At this command the both passage directions open either for 5 sec. each or until the
passage has been effected in the given direction or until the command
«Always locked»
is received. The command is ignored for the passage direction, which status at the
moment of its receipt is
«Always free»
.
Free passage in the direction A (open for free passage in the direction A)
Active front is at the contact
“
Unlock A
”
while there is a low level at the contact
“
Stop
”
and
a high level at the contact
“
Unlock B
”,
or active front is at the contact
“
Stop
”
while there is a low level at the contact
“
Unlock A
”
and a high level at the contact
“
Unlock B
”.
At this command the passage direction A opens until the command
«Always locked»
is
received; the status of the passage direction B does not change at that.