User Instruction Manual
36
User Name:the user of the remote controller. It can be empty.
Wireless siren coding: when the built in siren of the host can not satisfied to
your demand, need external wireless siren.please press the wireless siren
coding button.
Wireless siren coding method: enable the wireless siren receiver,press [save]
key of the siren, left click wireless siren coding from the VGA, when you hear
the voice prompt, means coding success, If delete the wireless siren, press
the CLR1 and CLR 2 at the same time for 1 minutes.
3.3.2.1.2 Zone setting
Includes [disabled][delay][perimeter][burglary][Emergency][24 hours][fire].
ID: the unique code of the wireless accessories,it can manual code or wireless
coding to get it. When setup the zone type, please check the accessories zone
No. Wireless zone(1-32), bus zone(33-96), wired zone(97-112).
Enable: If activate the certain zone, please choose the enable.
Delete: refer to delete single wireless accessories.
Delete All: refer to delete all the wireless accessories.
Address: it is the location where the zone is installed.
Type:refers to the alarm types that the detector may report the alarms to the