background image

User Instruction Manual

36

User Name:the user of the remote controller. It can be empty.
Wireless siren coding: when the built in siren of the host can not satisfied to
your demand, need external wireless siren.please press the wireless siren
coding button.
Wireless siren coding method: enable the wireless siren receiver,press [save]
key of the siren, left click wireless siren coding from the VGA, when you hear
the voice prompt, means coding success, If delete the wireless siren, press
the CLR1 and CLR 2 at the same time for 1 minutes.

3.3.2.1.2 Zone setting
Includes [disabled][delay][perimeter][burglary][Emergency][24 hours][fire].
ID: the unique code of the wireless accessories,it can manual code or wireless
coding to get it. When setup the zone type, please check the accessories zone
No. Wireless zone(1-32), bus zone(33-96), wired zone(97-112).
Enable: If activate the certain zone, please choose the enable.
Delete: refer to delete single wireless accessories.
Delete All: refer to delete all the wireless accessories.
Address: it is the location where the zone is installed.
Type:refers to the alarm types that the detector may report the alarms to the

Summary of Contents for i Alarm DVR

Page 1: ......

Page 2: ......

Page 3: ...latform easily realizes video linkage alarm alarm video control PTZ control remote set query The system uses the Linux operating system to ensure the system stability and reliability with a variety of network interfaces using TCP IP protocol LAN WAN remote transmission automatic warning automatic alarm automatic recording and other functions EAVS s highly integrated features effectively solve the ...

Page 4: ...alarm and video surveillance is a powerful combination of proven intelligent alarm monitoring is an important direction for future development but also the establishment of large scale technology base alarm monitoring system With the large scale development of intelligent alarm monitoring for urgent needs EAVS digital alarm surveillance video server plays a great role in promoting The set up of EA...

Page 5: ...17 2 8 Mouse Operation 20 Chapter 3 Host Operation 22 3 1 Menu of Host System 22 3 2 System of Settings and Operation 23 3 2 1 User Log in 23 3 2 1 1 Host start up 23 3 2 1 2 System Log in 23 3 3 Menu Operations 24 3 3 1 System Configuration 24 3 3 1 1 Basic Setting 25 3 3 1 2 User Setting 26 3 3 1 3 HDD Setting 27 3 3 1 4 Default Setting 28 3 3 1 5 System Operation 28 3 3 1 6 System Maintenance 2...

Page 6: ... HDD Loss 45 3 3 3 4 Video Blind 45 3 3 4 Electric Switch 46 3 3 5 Simulation 48 3 3 5 1 Encoding Setting 48 3 3 5 2 Recording 49 3 3 5 3 PTZ 50 3 3 5 4 Mosaic Setting 53 3 3 5 5 Timing Color 53 3 3 5 6 Polling Setting 54 3 3 6 Digital Camera Setting 55 3 3 7 Network 56 3 3 7 1 DHCP Dynamic Host Configuration Protocol Configuration 56 3 3 7 2 1 PPPoE Configuration 58 3 3 7 2 2 DDNS 58 3 3 7 2 3 FT...

Page 7: ...sion algorithm which may realize independent hardware compression with CIF resolution of 25 frames per second It supports both VBR and variable frame rate The coded stream of video image can be set during the process of setting the quality of video image It supports at most 16 channels audio video signals Each channel of audio video signal is compressed in real time by independent hardware to ensu...

Page 8: ...quipment It can control the rotation of PTZ and relevant parameters of camera like aperture size focal I length etc Remote alarm and system log view Video search and real time playback Powerful networking functions with various linking methods Remote internet access supports multi screen display 5 Video Playback Multiplex each channel can play real time video independently and realize playback and...

Page 9: ...supports HDMI HD output interface It can view the local or remote system logs 7 Sound Functions It supports up to 16 linear audio input 1 channel audio output 1 MIC input a headphone output It has the functions of audio and video synchronous input The sound is very clear and smooth and without any noise It can monitor the image and sound simultaneously It supports the video camera with audio funct...

Page 10: ...larm CMS telephones and 4 personal alarm telephones It supports PC downloading IE downloading and telephone remote control programming Contact ID protocol and MEIAN II bus protocol The built in electronic clock can realize 4 groups arming and disarming per day It can internally and externally connect alarm sound to make alarm linkage output Automatic learning code pattern recognition of wireless s...

Page 11: ...evice cannot be reused until it is checked by the special technical personnel If any problem occurs please contact special technical personnel or supplier Do not repair it by yourself Installation Position Choose proper installation position to make air flow freely around the device so as to avoid overheat of the device Do not install the device near the heat sources like radiator and ventilating ...

Page 12: ...e service Zone number and tail resistance should refer to the real product 2 2 Open Package and Accessories Inspection After opening the package please check if there are any deformations or other kinds of damages to the device and accessories If any please do not use and contact with your supplier at the same time please check the integrity of all the accessories of the device The complete config...

Page 13: ...e switching signals Therefore the wired zone use 2 2kΏ line end resistance to monitor If the system detects there is 2 2kΏ resistance on the circuit it means the system is in normal condition if the system detects the resistance on the circuit is zero short circuit or infinite circuit break it will make alarms As the output modes of detectors are different the connection modes of resistance are al...

Page 14: ...ounters generally without sound and bedside generally with sound It can define if the siren works or not on site The alarm information can be reported to the central station during the process The area is not controlled by arming or disarming 10 Fire alarm zone It is used for the 24 hour monitoring of smoke detectors and heat detectors When the area is triggered the fire alarm will be made The sir...

Page 15: ...y arming While the host device is in the state of alert by the artificial setting some functions of the detectors may be enabled and other functions may be disabled It not only has effective safety functions but also allows people to move freely in the alarming space 18 Self learning code It refers to the setting process of establishing communication between wireless detectors and alarm host devic...

Page 16: ...ask setting to avoid displaying these fields and ensure the security of the privacy 3 UPNP Universal Plug and Play it is a common name for a group of protocols In simple words UPNP is equal to automatic port mapping 4 DDNS DDNS is to map user s dynamic IP address to a fixed domain name service When user is connecting to the network the client program will transfer the dynamic IP address of the hos...

Page 17: ... when switch VAG to monitor the icon will bright 4 Connectivity When link to the internet success the icon will bright 5 Product logo bright as power on status 6 HDD status HDD1 connected HDD2 connected HDD error status keep bright 7 1 in normal status display the system time 2 when occurs zone faulty FAU zone No Example when zone 3 faulty will display FAU 3 When multiple zones faulty it will disp...

Page 18: ... light on 11 away alarm in away alarm status light on 12 disarm in disarm status light on 13 telephone line faulty in telephone line faulty light on 14 alarm indication when alarms the light flashes 15 back up batteries voltage on in batteries voltage Off in battery normal 16 3G connectivity status in 3G status on ...

Page 19: ...utput Alarm input 4 8 16 channel wired device 24 32 56 channel wireless device 8 wireless remote control device RS485 port 1 RS485 port Network interface 1 RJ45 10M 100M adaptive network interface HDD interface 2 SATA HDD interface Mouse port 1 USB2 0 port USB port 1 USB2 0 1 USB1 1port Telephone line port 1 in 1out 2 groups of terminal port Power interface 1 DC input Audio video parameter Monitor...

Page 20: ...User Instruction Manual 20 Audio output rate 24Kbps Others Power input AC 110 24V DC 15V Working temperature humidity 10 60 10 90 2 5 Connection Diagram ...

Page 21: ...nect the wired cable on the status of power on Used 12V DC sealed lead acid battery and exchange the battery per 3 to 5 years Keyboard auxiliary power siren ect total power supply demand can not exceed to the maximum power of the host The battery maximum charging current is 350mA 2 6 System Connection Diagram ...

Page 22: ...ired zones maximum support 8 remote control 32 wireless zones It supports contact ID protocol alarm information can be uploaded to the CMS telephone line can also be used to remotely arm and disarm A four dimensional joystick keyboard can control 8 digital network alarm server at the same time ...

Page 23: ...d to the client CMS platform EAVS series product is simple to operate easy to use and fully compatible with alarm video network performance is very powerful it is a network alarm video server of high performance cost ratio on the market today 2 7 Remote Controller Description As for the operation of this device the button ENTER on the remote controller is the same as the function of clicking the l...

Page 24: ...User Instruction Manual 24 ...

Page 25: ...et point SCAN Set and call out automatic scanning lines GROUP Group command Switch video interface to 1 4 8 16 screen modes Switch between full screen and small screen Fast rewind press button to restore normal play speed Fast play press button to restore normal play speed MENU Press this button on the preview screen to display the main menu Manual video recording Start End key Pause and start pla...

Page 26: ...of the machine panel Click the right mouse button 1 enter system main menu click the right mouse on the real time preview screen 2 Exit the current menu do not save the contents of certain setting menu and exit by clicking the right mouse button 3 Exit playback screen click the right mouse button to exit the video playback screen Click the left mouse button 1 left click the icon of function menu o...

Page 27: ... input box to activate soft keyboard Click the right mouse button to switch Chinese and English typewriting of the soft keyboard Click the numbers symbols and uppercase and lowercase letters on the soft keyboard to input 2 To input numbers firstly right click the number box to pop up number soft button and lastly click the left mouse button to exit the number soft keyboard Mouse movement 1 In the ...

Page 28: ...User Instruction Manual 28 ...

Page 29: ...ing and the system works in normal condition Note If the host device is on while on HDD is installed or HDD is installed but not detected it will display not connected storage devices on the video preview screen 3 2 1 2 system log in The default user name is admin no password required User may directly log in the main menu Based on the greater safety considerations please enter into system user se...

Page 30: ...ave to be saved as soon as the save button is pressed If directly exit all the setting will not work The legend means selected means not selected When the cursor is moved to an option the corresponding remark and explanation will automatically display in the bottom of the interface 3 3 1 System Configuration Move the cursor to the icon of system press the enter button on the remote controller or c...

Page 31: ...ng is PAL used in video signal standard Resolution VGA 1024 768 1280 1024 1440 900 1920 1080 Contrast Set the menu transparency in the VGA 7 is the highest without transparency Channel type Set the channel s video mode 4 960H 2 720P 2 1IPC 4 IPC At present support 100 megapixel 130 megapixel 200 megapixel device System Time Change the current date and time of the device Note change the time will c...

Page 32: ... and the backup HDD also overwrote It will recycle to overwrite the earliest video file Note The SYSTEM TIME can not free to change otherwise it will cause check the video failed If change the system time before the current time all the video file will be delete after the new time Please do not free to change the system time 3 3 1 2 User Setting Move the cursor to the user setting press the enter ...

Page 33: ...button from remoter or click up the left button from the mouse to get the following interface ID maximum support HDD qty Status HDD status connected or disconnected Total HDD maximum capacity free means surplus capacity Format delete all the HDD data Before recording please make the HDD format first ...

Page 34: ...activate this function the related setting will restore to the default factory Please be careful 3 3 1 5 System operation System upgrade please store the upgrade file save to the root of the U disk Insert the U disk into the USB 2 0 slot Press the confirm to upgrade the system It will show the progress dialog ...

Page 35: ...ulti select If setup system will restart every week as your demand 3 3 2 Zone Configuration Alarm includes Basic setting Alarm link Timing alarm Alarm inquiry 3 3 2 1 Basic setting Includes remote zone system alarm receive user phone No password GPRS 3 3 2 1 1 Setup remote controller ID the unique code of the wireless remote controller Can directly input the code No Of the remote controller or pre...

Page 36: ...ss siren press the CLR1 and CLR 2 at the same time for 1 minutes 3 3 2 1 2 Zone setting Includes disabled delay perimeter burglary Emergency 24 hours fire ID the unique code of the wireless accessories it can manual code or wireless coding to get it When setup the zone type please check the accessories zone No Wireless zone 1 32 bus zone 33 96 wired zone 97 112 Enable If activate the certain zone ...

Page 37: ...Home Arming Disarming Note 1 means the host device will give alarms when the type of alarm is triggered 2 X means the host device will not give alarms when the type of alarm is triggered By default the wireless zones are effective while the wired zones are all disabled The Siren Type can be set according to the requirement It is recommended to set different siren sounds in accordance to different ...

Page 38: ... will delay the alarm when the alarm is triggered The default setting is 10s Exit delays it refers to the period 001 255 seconds in which allows users to exit the zone before alarming is activated after setting arm manually or by remote controller The default setting is 10s Siren time the siren ring time in alarming the default is 5 minutes It is recommended not to set over 15 minutes Ring times u...

Page 39: ...rs alarm exceed to 3 times at a time The host system assumes that problem as false alarm It will not report the alarm information to CMS Default is disable Been uploaded to the CMS the host device normally report the alarm information to the CMS through the TCP IP if network faulty or uploaded failed the host device will upload through the PSTN way If choose this option the host device surely comp...

Page 40: ... and again Default setting is 5 times CMS test time used in the heartbeat testing between host panel and CMS Can set 0 999 hours 3 3 2 1 5 Setup User Voice Phone No It can set 4 user voice phone No which all receiving alarms by land line mobile phone way Most can input 15 digital Keep saved after setting Dial to user phone No times when user receive the alarm phone failed in several times it will ...

Page 41: ...ms of CMS The host device sends alarm messages with ADEMCO CONTACT ID communication protocol format If the host device receives the recognition signal it means the alarm is successfully reported Otherwise the host device will give alarms repeatedly The alarm message is displayed and processed by the computer program of CMS Receiving alarms by using ordinary voice phone Once the detector is trigger...

Page 42: ...ss will continue If the user does not press 1 to clear the alarms or press 3 to disarm system the host device will continue to dial other preset telephones to report the alarm After the alarm is cleared the host device will restore to the original state before alarming Remote Control Use other phones to dial the phones connected to the host device The host device will automatically pick up the pho...

Page 43: ...make arm disarm and voice phone control ect 3 3 2 1 7 GPRS setup Please check and confirm the SIM card comply with GSM module requirement before activating the GPRS function GSM Enable Make calls and text messages GPRS Enable GPRS flow to access to the network and make alarm GPRS APN SIM card operator access point GPRS User Name GPRS user s name GPRS Password The GPRS password of the SIM card ...

Page 44: ...3 to the specified email address and report the alarm information video photo to CMS Operation steps as below Please set email before operation refer to the 3 3 2 4 Please set the CMS configuration before operation Set zone No 03 Choose send email Choose report CMS Choose record for selected zone channel No 3 Choose taking photo for selected zone No 3 Press Save button ...

Page 45: ...p the left key by mouse to enter into below setting Under this options User can link the corresponding alarm zones channels preset point etc when one of burglar zones alarms the corresponding channel s video will taking photoes record video according to the preset setting And DVR will send email or report the alarm information to the alarm CMS If the record video and taking photo not set the DVR o...

Page 46: ...g arm disarm hour minutes set as 0 refer to disable the function 2 The 4 group of timing arm disarm can not overlap otherwise it will cause this period can not be valid 3 If set the first period is later than the second period time for a example 17 30 8 00 the correspond period is first day 17 30 8 00 second day 4 All of the timing arm disarm setting only in valid for the burglar and perimeter ala...

Page 47: ...uery Includes wireless remote controller and zone s information ID refer to unique ID code for the wireless accessories Zone Type includes burglary delay perimeter 24 Hour Emergency Fire Disable Zone Name refer to wireless accessories installation location ...

Page 48: ... The system will automatically take proper actions in respond to the changes of the screen status someone is passing or the lenses are moved It can set arm and disarm time detection sensitivity and detection areas When it is triggered it will link the video recording alarm output and the rotation of camera to its proper preset position ...

Page 49: ...il when you define the motion detection if there is a objection enter into the setting areas The device will capture the photo and send to the mailbox Sound Alarm if enable the sound alarm when you define the motion detection Report CMS if report to the CMS when you define the motion detection Call User if dial to the user when you define the motion detection Zone Setting each channel has its own ...

Page 50: ...ve and click up the button of four different areas it can be set each areas separately 3 3 3 2 Video Loss When the video camera are in correspondence with each channel have no input signals DVR will alarms according to below alarm linkage as preset to work Channel checking the loss signal of the channel according to the needs Siren Tone enable or disable the siren tone Send Email enable or disable...

Page 51: ... soon as objects enter into the defined areas Auto Restart automatically restart the host system when HDD abnormality 3 3 3 4 Video Blind When the video camera lens are be covered by the unknown object Host Device will alarms according to below preset to work Sensitivity define the times of the covered lens It can adjustable from 1s 10s Enable enable the video blind function or not Arm Disarm Link...

Page 52: ...period Beyond of this regular period is invalid 3 3 4 Electric Switch Switch No The No of the switch Switch Status display the current status of the switch ID the unique ID code of the switch Switch Command enable or disable the corresponding switch Regular time user set the regular time according to the needs if activate this function please make sure to choose the option box Everyday you can set...

Page 53: ...tric Switch Status inquiry all the switch current status Send send out the operation command to control the corresponding switch When timing arm disarm hour minutes set as 0 refer to disable the function The 4 group of timing arm disarm can not overlap otherwise it will cause this period can not be valid If set the first period is later than the second period time for a example 17 30 8 00 the corr...

Page 54: ...d 960H Picture quality divided into best better good general bad Frame rate can set 1 25 the higher the better for the video quality Default setting is 25fps Sub stream Setting If it needs phone browsing then the Phone Browse should be activated It is recommended not to change the resolution and keep QCIF format The videos with higher frame rate have higher video quality The default maximum frame ...

Page 55: ...lar Time It can set 4 group of timing recording per day The starting time of each period should be earlier than the finishing time The start time of the second period should be later than the finishing time of the first period When the check mark appears in the box before Enable it means the time period is selected Note ...

Page 56: ...day in week refers to each day While All in channel means all the channels 3 3 5 3 PTZ First to setup the address of dome Then make sure A line and B line of dome are correctly connected to the A port and B port on the device Channel Choose the access channel of dome camera PTZ Protocol Choose the protocol in accordance with the type of dome example PELCO P PELCO D Address Set dome address the def...

Page 57: ...rotation of PTZ camera Preset Setup Rotate the camera to the desired position by pressing the directional buttons click the preset button and input preset value Click setup to save the setting Preset Call choose a channel input a preset value in the input box and then click call button to call the preset value Pattern Cruise Choose a channel input a preset value in the pattern box and then click c...

Page 58: ... of pattern scanning has to be done in PTZ setting In this screen it can only be called Video Inquiry Playback Press the below icon enter into the video inquiry and playback menu Video Type Includes All Timing Manual Video Alarm Video and Motion ...

Page 59: ...may use mask setting to avoid displaying these fields and ensure the security of the privacy Note Mosaic can set 4 different areas at the most click up to each channel s setting to set occlusion areas separately Long press left button and Move the mouse to set the designated area click up the left button in the designated area to cancel the current setting Click up the right button in the designat...

Page 60: ...ble channel s timing color setting before operation And do not overlap each period 3 3 5 6 Polling Setting Screen interval s display the intervals of selected channel in turn only if the channel is selected the function can be effective ...

Page 61: ...he channels 8 CH host Split 9 the host monitoring screen display 1 9 channels 16 CH host Split 16 the host monitoring screen display all the channels 16 CH host 3 3 6 Digital Camera Setting Digital Camera refer to access to the streaming video is IP camera before setting the IP camera please make sure the channel type includes IP camera mode System basic setting device setting channel type After t...

Page 62: ...g you can press button connection 3 3 7 Network Network includes Basic Setting Advanced Setting CMS Setting Time Syn IP Filter 3 3 7 1 DHCP Dynamic Host Configuration Protocol Configuration Default IP Address 192 168 1 66 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 Main DNS It refers to the IP of local primary domain name server on network used by the main host Mac Address Assigned by th...

Page 63: ...the requirement The recommended port number is from 1024 to 65500 Port mapping is actually one of the NAT address translation Its function is to translate the public network address to the private address The ADSL broadband router using routing mode has a dynamic or fixed network IP The ADSL router is directly connected to the HUB or switching equipment and all the computers are in the internet sh...

Page 64: ...w to browse on the intranet and extranet Extranet browsing WEB browsing http test 3322 org 2001 IE browsing Video browsing http test 3322 org 2002 Client browsing Phone browsing http test 3322 org 2003 phones should be the supported models Intranet browsing WEB browsing 192 168 1 69 3000 IE browsing Video browsing 192 168 1 69 3001 client browsing Phone browsing 192 168 1 69 3002 phone should be t...

Page 65: ...edial and obtain new IP address 3 3 7 2 2 DDNS Configuration DDNS is to map users dynamic IP address to a fixed domain name service when user is connecting to the network the client program will transfer the dynamic IP address of the host device to the server program on the ISP s server by means of information transfer And the server program will be responsible for providing DNS services and reali...

Page 66: ...e world and access the servers to obtain large amount of programs and information The main function of FTP is to enable users to connect a remote computer on which FTP server program is running to check what kind of files there are on the remote computer And then copy those files from the remote servers to the local computer or send the files on the local computer to the remote servers To set FTP ...

Page 67: ...rver domain name for sending mail 2 input recipient address 3 Input send address which can be the same as the recipient address 4 input the password of send mail 5 click save button The user has to apply for an E mail box which supports SMTP In case of alarms the device will automatically log in the E mail and send alarm pictures and alarm information in the E mail box for the purpose of searching...

Page 68: ...n to the CMS you have to apply and register and ID If there are other CMS available for uploading the CMS IP should be changed to the required IP Enabling and disabling CMS require the restarting of the device Heartbeat Time it refers to a period after which the device will send a signal to alarm CMS If the signal is not set in the heartbeat time CMS will give alarm ...

Page 69: ...ith the GPRS 3 3 7 4 Time Syn It includes time zone server port No time syn interval 3 3 7 5 IP Filter Under below setting can permit to access to the host device s IP or forbid to access to the host device s IP If enable the black list the IP from the black list can not access to the host device ...

Page 70: ...ation Under below setting can browse the channels alarm input alarm output hardware version software version release date serial number hardware type Please learn of version info in advance when upgrade the system or consult customer service ...