Related Zone No.: it is required to associated with 2 neighboring wireless
devices in case of preventing from false alarm. Within user set time, trigger
two devices, the host will alarm, only trigger one of them, the host device will
warn you:[You have entered private place,please exit quickly].
Note:
When use the related zone, we ‘ll not suggest to use door contact sensor
devices for suspected safety defects. Please do not overlap the related zones.
It may lead to different alarm and unexpected functions.
3.3.2.1.3 System Setting
Enter delays: it refers to the period(001-255 seconds) in which the host device
will delay the alarm when the alarm is triggered. The default setting is 10s
Exit delays: it refers to the period(001-255 seconds) in which allows users to
exit the zone before alarming is activated after setting arm manually or by
remote controller. The default setting is 10s
Siren time: the siren ring time in alarming( the default is 5 minutes). It is
recommended not to set over 15 minutes.
Ring times: user remote control the host device through the phone call. Dialing
the host device telephone No. the No of host device off-hook ringings. It can
set 0-99, setup 00 to disable the remote phone control operation
functions(default factory setting is 7 times).
Detector lost test time:it refers to the time interval of detector loss or wireless
detector battery voltage.
AC loss delay report: AC loss inspection, 0 is default setting(enable).