background image

Innovative DisplayWorks, Inc.

To locate the distributor in your area go to: http://www.idw.global/contact/#distributors

Summary of Contents for G-10-F33EB

Page 1: ...Series Cooler Instruction Manual G 10f GCG 10f UPRIGHT COOLER Manual is for the following models G 10F G 10 F33EB GCG 10F GCG 10 F33EB GCG 10F2 GCG 10 F233EB G 10 F33EB HC GCG 10 F33EB HC GCG 10 F233EB HC ...

Page 2: ...Manual is for the following models G 10F G 10 F33EB GCG 10F GCG 10 F33EB GCG 10F2 GCG 10 F233EB G 10 F33EB HC GCG 10 F33EB HC GCG 10 F233EB HC G 10f GCG 10f Instruction Manual ...

Page 3: ...ons 4 Features 5 Instructions 5 Flammable R290 Warnings 5 Ambient Environment 5 Preparation Before Operation 6 Replacing the Interior Light 7 Replacing the Door LED Lights 8 Setting Up Power Cord Holder 8 Startup Operation Temperature Adjustment 9 Lit Door Logo Switch 9 Repair Maintenance for Refrigeration Drawer 9 Condenser Maintenance 10 Maintenance 10 Cleaning Shutdown Questions Answers 10 Reve...

Page 4: ...Instruction Manual 3 ...

Page 5: ...ned for freestanding installation only 8 Do not operate or store your cooler near or around explosive fumes gasoline or other flammable vapors and liquids 9 Setting the temperature control to the 0 position does not remove power to the light circuit perimeter heaters or evaporator fans Please save these instructions DANGER Proper Disposal of the Refrigerator To prevent any risk of child entrapment ...

Page 6: ... place cooler in below normal temperatures Do not place cooler in extreme humid environments this may cause components to rust Do not place cooler near constant running or splattering water this may cause immediate damage to refrigeration system Must allow at least 4 between rear of cooler and wall for proper ventilation and heat dissipation of cooler Do not place furniture or other articles with ...

Page 7: ... Leveling Set unit in its final location making certain there is adequate ventilation in the room WARNING Warranty is void if ventilation is insufficient Proper leveling of the G 10f GCG 10f cooler is critical to it operating correctly Condensation removal and door operation will be affected by leveling The cooler should be leveled front to back and side to side with a level Ensure that drain hose...

Page 8: ...R LIGHT 1 Press two sides of plastic cover by the fingers and remove it 5 To install LED lights follow the above directions in reverse order 2 Disconnect the lights 4 Remove LED light strand 3 Unscrew 3 screws using a Phillip s screwdriver 7 ...

Page 9: ... instructions in reverse order Notes If there are any malfunctions with the main control panel of LED lights please contact a professional for replacement SETTING UP SPACER POWER CORD HOLDERS The G 10f GCG 10f is supplied with one set 2 pieces of Spacers to hold the extra length of Power Cord 1 Take out the two Spacers and screws supplied in the Accessory Pack shipped with the Cooler 2 Use a Phill...

Page 10: ...move the screws from the front grill and then remove the grill 3 Unplug all connections and terminals that are in need of repair 9 G 10f GCG 10f performance testing position of the thermostat is around 4 6 Component shown at the left functions as a secondary power source for low voltage items such as signs 4 Using a screwdriver remove the 3 screws from the refrigeration drawer base plate 5 Slide t...

Page 11: ...is used shown left 5 Replace grill and utilize the Phillips screwdriver to tighten the screws into place replace the rubber caps MAINTENANCE Cleaning Shutdown Questions and Answers Cleaning and Maintenance 1 Unplug the cooler before cleaning 2 Use a soft cloth or sponge with water or soap non corrosive mild detergent while cleaning After cleaning wipe the cooler using dry cloth to keep the cooler ...

Page 12: ...sert it into left bottom hinge 3 disassemble the right upper hinge then remove the door 1 disassemble the the hinge latch of left hand door 2 disassemble the front grill disconnect the terminals then hide the terminals into door s reserved hole 4 draw out the structure of self closing door then assemble the structure into door other side 5 clockwise rotate the door 180 Delete clause 1 in the left ...

Page 13: ...s reserved hole then get through hinge axie connect the terminals 10 assemble the front grill complete the reversible door exchange 9 fix the upper hinge into left axie sleeve then anticlockwise rotate the hinge to right position to fasten it 8 clockwise rotate the left axie sleeve 60 8 Remove door limit from right hinge into corresponding holes on left hinge 9 Feed the wiring terminals through th...

Page 14: ... FUSE REPLACING THE FUSE 1 Unplug the cooler 2 Remove the screws from the back grill and then remove it 3 Open the cover of the fuse block as shown in the image to the left 4 Unscrew the fuse box then replace the bad fuse 5 After repair re install all parts reversing steps 1 5 ...

Page 15: ...the door and lock assembly to avoid children accidentally becoming trapped inside the cooler AFTER SALES SERVICE Any product has the possibility of malfunction Please observe the cooler s operation and any changes to product being stored If there are any abnormal cases refer to the table below If there is still no change after following the below instructions please inform our service center in a ...

Page 16: ...age protector B Power supply for LED lights C On Off switch for interior and door side light D1 Interior top LED light D2 Door side LED light E Evaporator Fan F Fuse G Socket H Thermostat I Condenser fan J Overload for compressor K Compressor L Compressor starting capacitor M Compressor relay ...

Page 17: ...ATOR FAN BK RD WH WH BK BK TEMPERATURE CONTROL CONDENSER UNIT WH BK AC 125V 3A FUSE SOCKET SWITCHING POWER SUPPLY INTERIOR LIGHT SWITCH RD CONNECTIONS FOR EMI70UER COMPRESSOR POWER CORD GN WH WH BK RD BK WH L1 L2 N TERMINAL BOX TO HARNES GROUND WH RD START CAPACITY BK S R 2 1 RELAY C 1 WH 3 2 CONDENSER FAN CONTROL UNIT TO SOCKET GN WH BK ...

Page 18: ...fan F Fuse G Socket H Thermostat I Condenser fan A Electric leakage protector B Power supply for LED lights C1 On Off switch for Interior light C2 On Off switch for lit door logo light D1 Interior top LED light D2 Door side LED light J Overload for Compressor K Compressor L Conpressor starting capacitor M Compressor relay ...

Page 19: ...Innovative DisplayWorks G 10f GCG 10f 18 GCG 10f ELECTRICAL WIRING DIAGRAM ...

Page 20: ...Innovative DisplayWorks Inc To locate the distributor in your area go to http www idw global contact distributors ...

Reviews: