Instruction Manual

Innovative DisplayWorks

4

INSTALLATION

Installation of the cooler must be done according to applicable local codes or equivalent. 

Ambient Environment

•  Place cooler on an even surface to reduce vibration and noise.

•  To transport, do not tilt the cooler beyond a 45 degree angle.

•  Do not place cooler in direct sunlight or near any heat sources.

•  Do not place cooler in environment temperatures that exceed 109°F.

•  Do not place cooler in below normal temperatures.

•  Do not place cooler in extreme humid environments, this may cause components to rust.

•  Do not place cooler near constant running or splattering water, this may cause immediate damage to refrigeration system.

•  Must allow at least 4” between rear of cooler and wall for proper ventilation and heat dissipation of cooler.

•  Do not place furniture or other articles with sharp edges near the cooler in order to prevent damage to the glass door.
•  This cooler is for indoor use.
•  Place unit in itʼs fi nal location, making certain there is adequate ventilation in the room.   

 

WARNING:

 Warranty is void if ventilation is insuffi cient.

PREPARATION PRIOR TO OPERATION

Unpacking

•  Remove all packaging materials before using cooler. This includes: foam pedestal, adhesive tape (used to fi x accessories) 

and protective gaskets.

•  Inspect cooler for concealed damage. Immediately fi le a claim with the freight carrier if there is damage. IDW is not 

responsible for damage incurred during shipping.

•  Cooler must remain unplugged in an upright position for 1 hour prior to use.

•  Clean the interior surface with a soft cloth and lukewarm water before operation.

•  Ensure that drain hose or hoses are positioned in the pan.

•  Remove plug and cord from inside the lower rear of the cooler.

•  The unit should be placed close enough to the electrical supply so that extension cords are not used.

Electrical Requirements

•  This model operates with a 110V/60Hz power supply.  Check the electrical outlet for proper voltage.

•  Dedicate one outlet for the use of the cooler.  

•  Do not use an extension cord or any other multiple connectors as this can lead to compressor failure.  

•  If the cord is damaged, it must be replaced.  

•  For your safety, plug the unit into a grounded wall outlet.  Please check with a certifi ed electrician for details.

WARNING:

  Do not use extension cords.

WARNING:

  Compressor warranties are void if compressor burns out due to low voltage.

WARNING:

  Power cord ground pin must NOT be removed!

Summary of Contents for G-77-N23EN

Page 1: ...G Series Cooler Instruction Manual Manual is for the following model G 77 N23EN G 77 ELECTRIC IMPULSE COOLER ...

Page 2: ...G 77 Instruction Manual Manual is for the following model G 77 N23EN ...

Page 3: ...n can be found on the inside of your cooler Keep your receipt with this manual for future warranty service Model Serial Date of Purchase TABLE OF CONTENTS Parts and Identification 2 Safety Instructions 3 Preparation 4 Location 5 Installation and Operation 5 Clamp Installation 5 Beverage Storage 6 Maintenance 6 Changing Graphics 7 Cleaning 8 Flammable R600a Warnings 8 Troubleshooting 9 Circuit Diag...

Page 4: ... Pan Cover 6 Drip Pan 7 Compressor 8 Bottom Plate 9 Thermostat 10 Power Cord 11 Power Cord Clip 12 Thermostat Wire 13 Transformer Connecting Line 14 Ground Line 15 Fan Ground Line 16 Condenser Fan 17 Caster 3 18 Thermostat Knob 19 Base Supporter 20 Caster with Lock 21 Lid 2 22 Lid Clip 2 23 Basket 24 Evaporator Baffle 25 Evaporator Fan Cover 26 Evaporator Fan 27 Evaporator Fan Grill 1 2 3 4 5 7 8 9...

Page 5: ...g its length the plug or the connector end 9 Do not operate or store your cooler near or around explosive fumes gasoline or other flammable vapors and liquids 10 Do not use flammable liquids to clean unit 11 Setting the temperature control to the 0 position does not remove power to the light circuit perimeter heaters or evaporator fans 12 Do not adjust the temperature control The temperature control...

Page 6: ...N Unpacking Remove all packaging materials before using cooler This includes foam pedestal adhesive tape used to fix accessories and protective gaskets Inspect cooler for concealed damage Immediately file a claim with the freight carrier if there is damage IDW is not responsible for damage incurred during shipping Cooler must remain unplugged in an upright position for 1 hour prior to use Clean th...

Page 7: ... INSTALLATION AND OPERATION Connect the Power Source After 30 minutes of operation the unit should show signs of cooling After the empty cooler has been operating for a period of 5 hours the unit can be loaded with products CLAMP INSTALLATION The clamp secures the lid assembly to the main body of the cabinet 1 Locate the 2 notches on the interior of the lid 2 Snap the 2 bolts into the notches of t...

Page 8: ...rimarily for storing beverage cans and plastic bottles Avoid putting glass containers in the cooler All beverage products should be properly sealed to avoid leaking into the cooler MAINTENANCE Accessing Cooler Components 2 Remove the baffler from cooler 3 Using a Phillips screwdriver unscrew the 4 screws at the base of the cooler 1 Remove the basket from the inside of the cooler ...

Page 9: ...ith the cooler cord Then reverse steps 1 5 4 The body of the cooler can now be worked free from the frame 2 Wedge the graphic under the plastic frame of the cooler 3 Remove the covering on the double stick tape to adhere the graphic in place 1 Place graphic around barrel making sure to align the grill holes in the graphic with the grill holes on the cooler to allow proper ventilation for the coole...

Page 10: ...eed this commercial grade product is an ideal choice for shopping malls supermarkets hotels etc Transparent glass doors are built with hollow toughened glass that provides a high level of heat insulation Clear doors allow for high product visibility The forced air system allows for fast cooling speeds which helps maintain a consistent temperature Adjustable shelves allow for a wide variety of prod...

Page 11: ...aled well There is insufficient clearance around the cooler The temperature is not set properly The cycling frequency will reduce when all of the cans reach the set temperature The following is not a malfunction It is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends REFRIGERANT The cooler utilizes R600a refrigerant SPECIFICATIONS Model Power Supply V Hz ...

Page 12: ...Instruction Manual CIRCUIT DIAGRAM 10 ...

Page 13: ...Innovative DisplayWorks G 77 ...

Page 14: ...Innovative DisplayWorks Inc To locate the distributor in your area go to http www idw global contact distributors ...

Reviews: