The  reed  relay  output  provides  both  N.O.  (normally  open)  and  N.C.  (normally  closed)  dry  contacts  in 
order to interface as universally as possible. Typically the Relay N.O. and Relay Common terminals will 
be connected in parallel to those of other "coin pulse" generating devices. The Relay Common contact has 
an automatically resettable fuse to protect the module from wiring errors and other problems. The Service 
Monitor input is used to sense if power to the equipment has been applied. The Wicket Reader monitors 
this  signal  to  determine  the  following;  a)  whether  to  charge  the  Start  Up  Amount  or  the  Increment 
Amount,  or  b)  whether  to  indicate  that  the  equipment  is  running  (Wicket  Reader  face  turns  white). 
Wickets  Administrator  is  used  to  configure  the  WR88  Wicket  Reader's  use  of  this  signal,  including 
enable/disable  and  whether  Service  Sense  logically  corresponds  to  a  high  or  low  voltage  sensed  at  the 
input.

 

  

One of the below wiring harnesses must be ordered with the WK-LV Module for field wiring: 
 
 
 

The  WK-WR-LV  wire  harness  has  16"  leads  and  is  intended 
for general purpose retrofit  interface. IDX can assist you with 
specific information on connecting to a variety of equipment.

 

Wire

 

Name

 

Description / Specification

 

1- Yellow

 

Power Hot

 

Power supply: 12-28VAC or 12-35VDC

 

2- Black

 

Power Common

 

Power Common - Ground

 

3- White

 

Service Monitor

 

Input threshold: 1.4VDC, 2K Ohms internal pull down. 28VAC/DC 
maximum.

 

4- Red/Gr n

 

Switch N.O.

 

5- Grey

 

Switch N.C.

 

6- Violet

 

Switch Com.

 

SPDT reed relay switch contacts: 
0.30Amps @ 60VDC maximum. - with automatic resettable fuse.

 

 
 
 
 
The WK-WR-LV-MT wire harness is 16" in length and 
is  terminated  with  a  connector  for  the  Maytag  Gen  1 
Debit Specification for laundry equipment.  

Wire

 

IDX Name

 

Maytag Name - Function Description / Specification

 

1

 

ServiceMonitor

 

Avail2 - Optocoupler emitter output for machine available signal.

 

2

 

--

 

Avail1 - Optocoupler collector for machine available signal: = PWR+

 

3

 

--

 

Enable1 - Optocoupler LED anode for debit pulse enable: = PWR+

 

4

 

Relay N.C.

 

Enable2 - Optocoupler LED cathode for debit pulse enable signal.

 

5

 

Power Hot

 

PWR+  - 26VDC @ 100mA max. for debit reader.

 

6

 

Power Common

 

PWR-  -  Power common for debit reader.

 

 
Note: Wickets Administrator must be used to program the WR88 Wicket Reader to enable it to generate 
the correct pulses and debit a Customer Wicket by the proper amount. See below for information about 
setting the configuration parameters for the WR88.  A separate PDF document for Maytag-specific setup 
instructions is available on the Web.  

Summary of Contents for WR88

Page 1: ...rial Port MDB Vendor Protocol Interface documentation for Turbo Accessories applications including Wickets Jackpot Registration Redemption and Night Access Door Control are found within the Turbo Acce...

Page 2: ...IDX can assist you with specific information on connecting to a variety of equipment Wire Name Description Specification 1 Yellow Power Hot Power supply 12 28VAC or 12 35VDC 2 Black Power Common Powe...

Page 3: ...l to determine the following a whether to charge the Start Up Amount or the Increment Amount or b whether to indicate that the equipment is running Wicket Reader face turns white Wickets Administrator...

Page 4: ...ch located on the left side of the enclosure configures the WK MDB Module as one device or the other The valid cashless addresses are 0x10 address 1 and 0x60 address 2 This provides a means for compat...

Page 5: ...Port Card Display Protocol WK CD Module The Card Display Protocol was developed by IDX at the request of various card acceptor manufacturers to provide interoperability of credit and debit card syste...

Page 6: ...4 If you have selected the MDB Vendor Protocol in the last step you will see most of the other controls on the screen become unavailable as they are irrelevant to vending machine or revalue station a...

Page 7: ...d or a competitor s timer with a Grace Time feature enabled This will cause the Wicket Reader to debit only the Increment Value for the first 20 seconds after the Service Sense input indicates the mac...

Reviews: