background image

PAGE 

3

 

DOC: 374B 

REV: 12-12

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION 

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

1. 

Read these instructions.

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water.

6. 

Clean only with dry cloth.

7. 

Install in accordance with the manufacturer’s in-
structions.

8. 

Do not install near any heat sources such as ra-
diators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.

9. 

Only use attachments/accessories specified by the 
manufacturer.

10. 

Refer all servicing to qualified service personnel.  
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord 
or plug is damaged, liquid has been spilled or ob-
jects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

SAFETY SYMBOLS

Labeling on products and the 

Installation Instructions & 

User Manual

 may use safety related graphical symbols 

as shown below to note safety requirements.

Lightning Bolt:

  The lightning flash with 

arrowhead symbol, within an equilateral triangle, 
WARNING symbol, is intended to alert the user to 
the presence of un-insulated 

dangerous voltage

 

within the product’s enclosure that may be 
sufficient in magnitude to constitute a risk of 
electric shock to persons or domestic animals.

Exclamation Point:

 The exclamation point 

within an equilateral triangle, CAUTION symbol, 
is in-tended to alert the user to the presence of 
important operating and maintenance (servicing) 
instructions, or a hazard that can damage equip-
ment.

Do not proceed beyond a WARNING or CAUTION notice 
until you have understood the hazardous condition and 
have taken appropriate steps.

SPECIFICATIONS

Electrical

Frequency Response  .................................................................................... ±0.5 dB

22 Hz - 22 kHz, Input Level = 0 dBu

Total Harmonic Distortion, THD  ....................................................................... <0.5%

22 Hz - 22 kHz, Input Level = 0 dBu

Signal-to-Noise Ratio, S/N  .............................................................................. >85 dB

22 Hz - 22 kHz, Input Level = 0 dBu

Compressor

Compression Threshold ............................................................................–15 dBu
Ratio ...................................................................................................................5:1
Attack Time ...............................................................................................22 mSec
Release Time ..................................................................................................1 Sec

Maximum Output (Line Output) ...................................................................... +5 dBu
Analog-to-Digital Converter, A/D ......................................................................... 24 bit
Internal Processing  .................................................................... 32 bit, Floating Point
Sample Rate  .....................................................................................................48 kHz
Latency (Through a maximum of 6 network switch hops)  ......................... 5.7 mSec

Mechanical

Desktop Size ......................................................................5.13” W x 5.32” H x 5.66”D

(Desktop mounting requires optional IEDA520DTB)

Wall Mount Size ..................................................................4.95” W x 4.95” H x 1.9” D
Wall Mount mounting ................................................................. 2-gang electrical box

1-gang electrical box (using adapter backbox)

Standards Utilized

Full-Duplex Operations  ...........................................................................  IEEE 802.3x
Fast Ethernet, 100Mbps  .......................................................................... IEEE 802.3u

The 524 Series specifically uses 100Base-TX

Data Terminal Equipment Power  ...........................................................  IEEE 802.3af

via Media Dependent Interface (PoE)

Connecting Cable

Digital Audio/Power/Control  .............................................................  CAT5e or better

For distances to a maximum of 100 Meters (approximately 300 feet) to the con-
nected switch. Cable installed and tested in accordance with ANSI/TIA/EIA 568B 
Standards.

Environmental

Operating Temperature Range  ............................

+32˚F to +104˚F (0˚C to +40˚C)

Storage Temperature Range  .............................–40

˚

F to +158

˚

F (–40

˚

C to +70

˚

C)

Power
Consumption

Supply Power .......................................................................................................<2W

Supply Voltage = 48VDC

NOTE: 

This unit is 

not

 compatible with 500, 510, or 520 series Announcement Control Systems (ACS).

Summary of Contents for IEDA524-H

Page 1: ...INSTALLATION INSTRUCTIONS IEDA524 H IEDA520DTB DIGITAL MICROPHONE STATION REV 12 12 DOC 369B IEDA524 H IED0520DTB DIGITAL MICROPHONE STATION Installation Instructions...

Page 2: ...lly compatible with IEEE 802 3af standard for Power over Ethernet PoE allowing the 524 to be powered directly from any standard off the shelf PoE switch The processing power for the 524 comes from the...

Page 3: ...ation software to function as one touch action buttons to trigger any of the following types of announcements or messages A live page to a designated zone group A recorded page to a designated zone gr...

Page 4: ...alert the user to the presence of important operating and maintenance servicing instructions or a hazard that can damage equip ment Do not proceed beyond a WARNING or CAUTION notice until you have und...

Page 5: ...tons These four buttons are used to activate announcements or messages on the announcement controller Their exact function is configured in the announcement controller software 5 Microphone Attachment...

Page 6: ...r 11 Group and Line Level Output Enable DIP Switches DIP switches 1 through 5 are used to set the group number for this microphone station This group number must match the system number of the announc...

Page 7: ...nstallation IEDA520DTB Desktop Base The IEDA520DTB is available as an option when a desktop mounting solution is preferred The IEDA524 H ships with the plastic back box that you can then use to attach...

Page 8: ...a console Figure 5 illustrates the process for mounting the unit in such an application The washers shown are optional and can be used to prevent the unit from being forced off of the box due to the k...

Page 9: ...balanced audio cable to the line level audio output connector using the supplied connector as shown in Figure 7 Ensure that DIP switch 8 is set to the ON position Connect the other end of the cable to...

Page 10: ...ailable group and mic number S Group Address Mic Number Not Used Line Out Enable Figure 8 524 DIP Switch Locations Group DIP Switch Settings Switch 1 2 3 4 5 Group 1 ON OFF OFF OFF OFF 2 OFF ON OFF OF...

Page 11: ...ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON...

Page 12: ...OFF ON OFF 92 OFF OFF ON ON ON OFF ON OFF 93 ON OFF ON ON ON OFF ON OFF 94 OFF ON ON ON ON OFF ON OFF 95 ON ON ON ON ON OFF ON OFF 96 OFF OFF OFF OFF OFF ON ON OFF 97 ON OFF OFF OFF OFF ON ON OFF 98...

Page 13: ...N ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 159 ON ON ON ON ON OFF OFF ON 160 OFF OFF OFF OFF OFF ON OFF ON 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OF...

Page 14: ...OFF ON ON ON ON OFF ON ON 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OF...

Page 15: ...H IEDA520DTB DIGITAL MICROPHONE STATION Line Level Audio Output Enable Switch 8 Line Output Enabled ON Line Output Disabled OFF DIMENSIONS 4 952 4 952 1 812 3 281 1 907 900 750 Figure 9 IEDA524 H 5 1...

Page 16: ...Electronic Designs LLC Innovative Electronic Designs LLC 1 502 267 7436 phone 9701 Taylorsville Road 1 502 267 9070 fax Louisville KY 40299 USA www iedaudio com INSTALLATION INSTRUCTIONS IEDA524 H IED...